TY - JOUR
T1 - Visualization of porosity and thermal conductivity distributions of Japanese apricot and pear during storage using X-ray computed tomography
AU - Karmoker, Poly
AU - Obatake, Wako
AU - Tanaka, Fumina
AU - Tanaka, Fumihiko
PY - 2019/10
Y1 - 2019/10
N2 - Distributions of thermo-physical properties: such as porosity and thermal conductivity of Japanese apricot and pear during storage were determined based on X-ray CT image analysis. Japanese apricot was stored at 25 °C, whereas pear was stored at 25 °C and 5 °C. Average CT value was determined based on a series of X-ray CT images captured for each whole fruit. At the end of storage period, the average CT value decreased in Japanese apricot and pear at 25 °C, whereas it was the almost same as pear stored at 5 °C. Porosity increased, whereas thermal conductivity slightly decreased at 25 °C in Japanese apricot and pear. As a result of the experiment, it seemed that the internal structure of pear stored at 5 °C was well maintained during storage. Conversely, void space progressed in Japanese apricot and pear during storage at 25 °C. The porosity and thermal conductivity distributions were visualized based on the CT image during storage.
AB - Distributions of thermo-physical properties: such as porosity and thermal conductivity of Japanese apricot and pear during storage were determined based on X-ray CT image analysis. Japanese apricot was stored at 25 °C, whereas pear was stored at 25 °C and 5 °C. Average CT value was determined based on a series of X-ray CT images captured for each whole fruit. At the end of storage period, the average CT value decreased in Japanese apricot and pear at 25 °C, whereas it was the almost same as pear stored at 5 °C. Porosity increased, whereas thermal conductivity slightly decreased at 25 °C in Japanese apricot and pear. As a result of the experiment, it seemed that the internal structure of pear stored at 5 °C was well maintained during storage. Conversely, void space progressed in Japanese apricot and pear during storage at 25 °C. The porosity and thermal conductivity distributions were visualized based on the CT image during storage.
UR - http://www.scopus.com/inward/record.url?scp=85075392498&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85075392498&partnerID=8YFLogxK
U2 - 10.1016/j.eaef.2019.11.002
DO - 10.1016/j.eaef.2019.11.002
M3 - Article
AN - SCOPUS:85075392498
SN - 1881-8366
VL - 12
SP - 505
EP - 510
JO - Engineering in Agriculture, Environment and Food
JF - Engineering in Agriculture, Environment and Food
IS - 4
ER -