T1 - Ultrasmall compact CMOS imaging system for bioluminescence reporter-based live gene expression analysis
AU - Olorocisimo, Joshua Philippe
AU - Briones, Jeric
AU - Sasagawa, Kiyotaka
AU - Haruta, Makito
AU - Takehara, Hironari
AU - Tashiro, Hiroyuki
AU - Ishida-Kitagawa, Norihiro
AU - Bessho, Yasumasa
AU - Ohta, Jun
N1 - Publisher Copyright:
© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
PY - 2021/11/1
Y1 - 2021/11/1
N2 - Significance: Gene expression analysis is an important fundamental area of biomedical research. However, live gene expression imaging has proven challenging due to constraints in conventional optical devices and fluorescent reporters. Aim: Our aim is to develop smaller, more cost-effective, and versatile imaging capabilities compared with conventional devices. Bioluminescence reporter-based gene expression analysis was targeted due to its advantages over fluorescence-based imaging. Approach: We created a small compact imaging system using micro-CMOS image sensors (μCIS). The μCIS model had an improved pixel design and a patterned absorption filter array to detect the low light intensity of bioluminescence. Results: The device demonstrated lower dark current, lower temporal noise, and higher sensitivity compared with previous designs. The filter array enabled us to subtract dark current drift and attain a clearer light signal. These improvements allowed us to measure bioluminescence reporter-based gene expression in living mammalian cells. Conclusion: Using our μCIS system for bioluminescence imaging in the future, the device can be implanted in vivo for simultaneous gene expression imaging, behavioral analysis, and optogenetic modulation.
AB - Significance: Gene expression analysis is an important fundamental area of biomedical research. However, live gene expression imaging has proven challenging due to constraints in conventional optical devices and fluorescent reporters. Aim: Our aim is to develop smaller, more cost-effective, and versatile imaging capabilities compared with conventional devices. Bioluminescence reporter-based gene expression analysis was targeted due to its advantages over fluorescence-based imaging. Approach: We created a small compact imaging system using micro-CMOS image sensors (μCIS). The μCIS model had an improved pixel design and a patterned absorption filter array to detect the low light intensity of bioluminescence. Results: The device demonstrated lower dark current, lower temporal noise, and higher sensitivity compared with previous designs. The filter array enabled us to subtract dark current drift and attain a clearer light signal. These improvements allowed us to measure bioluminescence reporter-based gene expression in living mammalian cells. Conclusion: Using our μCIS system for bioluminescence imaging in the future, the device can be implanted in vivo for simultaneous gene expression imaging, behavioral analysis, and optogenetic modulation.
KW - bioluminescence
KW - biophotonics
KW - gene expression
KW - image sensors
KW - luciferase
KW - micro-CMOS
UR - https://www.scopus.com/pages/publications/85120881405
UR - https://www.scopus.com/pages/publications/85120881405#tab=citedBy
U2 - 10.1117/1.JBO.26.11.116002
DO - 10.1117/1.JBO.26.11.116002
M3 - Article
C2 - 34734515
AN - SCOPUS:85120881405
SN - 1083-3668
VL - 26
JO - Journal of Biomedical Optics
JF - Journal of Biomedical Optics
IS - 11
M1 - 116002
ER -