抄録
A new type of two-dimensional position sensitive gas counter for transmission counter with a backgammon-shaped flat electrode has been developed. The two dimensional position read-out can be achieved with the combination of a backgammon-shaped flat electrode read-out as horizontal position and the drift time measurement read-out as vertical position. The gas counter is designed as a transmission trajectory counter that can be used to determine angle of incident charged particles in charged particle detecting system. To check the characteristics of this gas counter, test experiments are performed with a coincidence plastic scintillation counter and β-ray source of 90Sr.
本文言語 | 英語 |
---|---|
ページ | 153-156 |
ページ数 | 4 |
出版ステータス | 出版済み - 1995 |
イベント | Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3) - San Francisco, CA, USA 継続期間: 10月 21 1995 → 10月 28 1995 |
その他
その他 | Proceedings of the 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference. Part 1 (of 3) |
---|---|
City | San Francisco, CA, USA |
Period | 10/21/95 → 10/28/95 |
!!!All Science Journal Classification (ASJC) codes
- 核物理学および高エネルギー物理学
- 放射線
- 放射線学、核医学およびイメージング