The laminar burning velocity of pre-mixed hydrogen-air mixtures was measured in a fan stirred combustion bomb. Unstretched laminar burning velocities and Markstein lengths were obtained at 0.10MPa for equivalence ratios of 0.4, 0.6, 0.8 and 1.0 using high speed flame imaging. The difficulties which arose whilst obtaining similar measurements at 0.25MPa and 0.50MPa are outlined. The turbulent burning velocity was measured at equivalence ratios of 0.4 and 0.8 from explosions carried out at 0.10MPa with turbulence intensities of 0.8 and 1.6m/s. Higher turbulent burning velocity ratios were observed for mixtures which yielded lower Markstein lengths in the laminar combustion experiments.