TY - JOUR
T1 - [The rapid analysis of polychlorinated quaterphenyls in blood using different diameter capillary column with the high-resolution gas chromatograph high-resolution mass spectrometer].
AU - Yasutake, Daisuke
AU - Ashizuka, Yuki
AU - Hori, Tsuguhide
AU - Kurokawa, Youichi
AU - Kajiwara, Jumboku
AU - Hirata, Teruaki
AU - Ishiguro, Yasuhisa
AU - Iida, Takao
AU - Uchi, Hiroshi
AU - Furue, Masutaka
PY - 2011/4
Y1 - 2011/4
N2 - The polychlorinated quaterphenyl (PCQ) concentrations in blood are important discriminative parameters in yusho patient. In this study, a rapid analytical method for PCQ using different diameter capillary column (rapid-Rtx65TG) with high-resolution gas chromatograph high-resolution mass spectrometer (HRGC/HRMS) instead of the gas chromatograph electron capture detector (ECD/GC) was developed. Using different diameter capillary columns, the analysis time of the HRGC/HRMS was drastically shortened, and the detection sensitivity was improved. In the rapid-Rtx65TG column, a small-bore capillary column (length 1m, I.D. 0.1mm) was connected with the inlet side of the GC, and behind that column, a large-bore capillary column (length 15mm, I.D. 0.53mm) for octadecachloroquaterphenyl (ODCQ) analysis was connected. In the HRGC/HRMS measurement of ODCQ by the rapid-Rtx65TG column, the minimum limit of detection for the apparatus was 0.4 pg, and the minimum limit of determination for the blood was 0.008 ppb. On ECD/GC in the conventional method and HRGC/HRMS in this study, the PCQ concentration in blood including yusho patients and yusho suspected persons was almost equivalent.
AB - The polychlorinated quaterphenyl (PCQ) concentrations in blood are important discriminative parameters in yusho patient. In this study, a rapid analytical method for PCQ using different diameter capillary column (rapid-Rtx65TG) with high-resolution gas chromatograph high-resolution mass spectrometer (HRGC/HRMS) instead of the gas chromatograph electron capture detector (ECD/GC) was developed. Using different diameter capillary columns, the analysis time of the HRGC/HRMS was drastically shortened, and the detection sensitivity was improved. In the rapid-Rtx65TG column, a small-bore capillary column (length 1m, I.D. 0.1mm) was connected with the inlet side of the GC, and behind that column, a large-bore capillary column (length 15mm, I.D. 0.53mm) for octadecachloroquaterphenyl (ODCQ) analysis was connected. In the HRGC/HRMS measurement of ODCQ by the rapid-Rtx65TG column, the minimum limit of detection for the apparatus was 0.4 pg, and the minimum limit of determination for the blood was 0.008 ppb. On ECD/GC in the conventional method and HRGC/HRMS in this study, the PCQ concentration in blood including yusho patients and yusho suspected persons was almost equivalent.
UR - http://www.scopus.com/inward/record.url?scp=79960999606&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79960999606&partnerID=8YFLogxK
M3 - Article
C2 - 21706895
AN - SCOPUS:79960999606
SN - 0016-254X
VL - 102
SP - 145
EP - 152
JO - Fukuoka igaku zasshi = Hukuoka acta medica
JF - Fukuoka igaku zasshi = Hukuoka acta medica
IS - 4
ER -