抄録
The goal of our study was to develop a computational framework for reconstruction of four-dimensional computed tomography (4D-CT) images during treatment time using electronic portal imaging device (EPID) images based on a dynamic 2D/3D registration. The 4D-CT images during treatment time ("treatment" 4D-CT images) were reconstructed by performing an affine transformation-based dynamic 2D/3D registration between dynamic clinical portal dose images (PDIs) derived from the EPID images with planning CT images through planning PDIs for all frames. Elements of the affine transformation matrices (transformation parameters) were optimized using a Levenberg-Marquardt (LM) algorithm so that the planning PDIs could be similar to the dynamic clinical PDIs for all frames. Initial transformation parameters in each frame should be determined for finding optimum transformation parameters in the LM algorithm. In this study, the optimum transformation parameters in a frame employed as the initial transformation parameters for optimizing the transformation parameter in the consecutive frame. Gamma pass rates (3 mm/3%) were calculated for evaluating a similarity of the dose distributions between the dynamic clinical PDIs and "treatment" PDIs, which were calculated from "treatment" 4D-CT images, for all frames. The framework was applied to eight lung cancer patients who were treated with stereotactic body radiation therapy (SBRT). A mean of the average gamma pass rates between the dynamic clinical PDIs and the "treatment" PDIs for all frames was 98.3±1.2% for eight cases. In conclusion, the proposed framework makes it possible to dynamically monitor patients' movement during treatment time.
| 本文言語 | 英語 |
|---|---|
| ホスト出版物のタイトル | Medical Imaging 2017 |
| ホスト出版物のサブタイトル | Physics of Medical Imaging |
| 編集者 | Taly Gilat Schmidt, Joseph Y. Lo, Thomas G. Flohr |
| 出版社 | SPIE |
| ISBN(電子版) | 9781510607095 |
| DOI | |
| 出版ステータス | 出版済み - 2017 |
| イベント | Medical Imaging 2017: Physics of Medical Imaging - Orlando, 米国 継続期間: 2月 13 2017 → 2月 16 2017 |
出版物シリーズ
| 名前 | Progress in Biomedical Optics and Imaging - Proceedings of SPIE |
|---|---|
| 巻 | 10132 |
| ISSN(印刷版) | 1605-7422 |
その他
| その他 | Medical Imaging 2017: Physics of Medical Imaging |
|---|---|
| 国/地域 | 米国 |
| City | Orlando |
| Period | 2/13/17 → 2/16/17 |
UN SDG
この成果は、次の持続可能な開発目標に貢献しています
-
SDG 3 すべての人に健康と福祉を
!!!All Science Journal Classification (ASJC) codes
- 電子材料、光学材料、および磁性材料
- 原子分子物理学および光学
- 放射線学、核医学およびイメージング
- 生体材料
フィンガープリント
「Reconstruction of four-dimensional computed tomography images during treatment time using electronic portal imaging device images based on a dynamic 2D/3D registration」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS