抄録
A PVT measurement apparatus by the Burnett method for the temperature range from room temperature to 250 °C and at pressures up to 100 MPa has been developed with a remote operation system. PVT measurements of hydrogen, helium and nitrogen have been accomplished up to 97 MPa. The density uncertainty of the present measurements at 80 °C is estimated to be 0.2 % from the deviations for nitrogen. An existing equation of state (EOS) for hydrogen agrees well with the present measurements within ±0.22 % at 80 °C. The systematic deviations between the EOS and the present measurements at 120 °C and 160 °C are shown with the maximum deviation of 0.52 % at 120 °C and 97 MPa.
| 本文言語 | 英語 |
|---|---|
| 出版ステータス | 出版済み - 2009 |
| イベント | 9th International Conference on Power Engineering, ICOPE 2009 - Kobe, 日本 継続期間: 11月 16 2009 → 11月 20 2009 |
その他
| その他 | 9th International Conference on Power Engineering, ICOPE 2009 |
|---|---|
| 国/地域 | 日本 |
| City | Kobe |
| Period | 11/16/09 → 11/20/09 |
!!!All Science Journal Classification (ASJC) codes
- 電子工学および電気工学
- エネルギー工学および電力技術
- 燃料技術
フィンガープリント
「PVT measurements of high pressure gas by the Burnett method」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS