TY - JOUR
T1 - Normal dose of pilsicainide showed marked negative inotropic effects in a patient who had no underlying heart disease
AU - Yoshida, Masayoshi
AU - Ando, Shin Ichi
AU - Chishaki, Akiko
AU - Makita, Naomasa
AU - Hasegawa, Yoshiyuki
AU - Narita, Sumito
AU - Momii, Hidetoshi
AU - Kadokami, Toshiaki
PY - 2014/2
Y1 - 2014/2
N2 - We report the case of an otherwise healthy 64-year-old female who developed cardiopulmonary arrest after the administration of pilsicainide for treatment of paroxysmal atrial fibrillation. She had had an episode of paroxysmal atrial fibrillation, but no liver dysfunction, renal dysfunction, or echocardiographic abnormality before her admission. On the day of admission and the following day, 50 mg of pilsicainide was administered intravenously over 10 min (total 100 mg). Shortly after the second injection, she developed marked bradycardia and hypotension and eventually fell into a state of pulseless electrical activity. Immediate cardiopulmonary resuscitation was started. Although application of a temporary pacemaker restored her heart rate, echocardiography revealed no left ventricular contraction. We started percutaneous cardiopulmonary support (PCPS) and intra-aortic balloon pumping (IABP). Her cardiac contraction gradually recovered and returned to completely normality 3 days after the onset. The patient was discharged in an ambulatory condition.
AB - We report the case of an otherwise healthy 64-year-old female who developed cardiopulmonary arrest after the administration of pilsicainide for treatment of paroxysmal atrial fibrillation. She had had an episode of paroxysmal atrial fibrillation, but no liver dysfunction, renal dysfunction, or echocardiographic abnormality before her admission. On the day of admission and the following day, 50 mg of pilsicainide was administered intravenously over 10 min (total 100 mg). Shortly after the second injection, she developed marked bradycardia and hypotension and eventually fell into a state of pulseless electrical activity. Immediate cardiopulmonary resuscitation was started. Although application of a temporary pacemaker restored her heart rate, echocardiography revealed no left ventricular contraction. We started percutaneous cardiopulmonary support (PCPS) and intra-aortic balloon pumping (IABP). Her cardiac contraction gradually recovered and returned to completely normality 3 days after the onset. The patient was discharged in an ambulatory condition.
UR - http://www.scopus.com/inward/record.url?scp=84897619627&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84897619627&partnerID=8YFLogxK
U2 - 10.1016/j.joa.2013.04.004
DO - 10.1016/j.joa.2013.04.004
M3 - Article
AN - SCOPUS:84897619627
SN - 1880-4276
VL - 30
SP - 68
EP - 70
JO - journal of arrhythmia
JF - journal of arrhythmia
IS - 1
ER -