TY - JOUR
T1 - Noninvasive assessment of liver fibrosis by dual-layer spectral detector CT
AU - Morita, Koichiro
AU - Nishie, Akihiro
AU - Ushijima, Yasuhiro
AU - Takayama, Yukihisa
AU - Fujita, Nobuhiro
AU - kubo, yuichiro
AU - Ishimatsu, Keisuke
AU - Yoshizumi, Tomoharu
AU - Maehara, Junki
AU - Ishigami, Kousei
N1 - Funding Information:
We thank Prof. Yoshinao Oda, Department of Anatomic Pathology, Kyushu University, for providing the pathological information for this manuscript. We also thank Prof. Masaki Mori, Department of Surgery and Science, Kyushu University, for providing the clinical information for this manuscript.
Publisher Copyright:
© 2021 Elsevier B.V.
PY - 2021/3
Y1 - 2021/3
N2 - Purpose: To elucidate the diagnostic ability of liver fibrosis using (1) liver parenchymal iodine density on equilibrium computed tomographic imaging and (2) extracellular volume (ECV) measured by dual-layer spectral detector CT. Methods: From April 2018 to June 2019, 68 patients [mean age, 62 years; 39 males, 29 females] underwent dynamic contrast-enhanced CT by a dual-layer spectral detector CT system before liver transplantation or liver resection. The iodine densities of liver parenchyma (I liver) and aorta (I aorta) were independently measured by two radiologists at the equilibrium phase. The iodine-density ratio (I-ratio) (I liver/ I aorta) and the CT-ECV were calculated. Spearman's rank correlation coefficient was used to analyze the relationship between the I-ratio or the CT-ECV and the fibrosis stage. A receiver operating characteristic (ROC) curve analysis was performed to determine the accuracy of the I-ratio and the CT-ECV for discriminating fibrosis stages. Results: For both readers, the I-ratio and the CT-ECV increased significantly as the fibrosis stage advanced (I-ratio: rho = 0.380 and 0.443, p < 0.01; CT-ECV: rho = 0.423 and 0.469, p < 0.01). The CT-ECV showed better diagnostic accuracy for staging fibrosis, and the area under the ROC curve values for discriminating F4 stage were 0.884 and 0.925. The two readers' cutoff values of the CT-ECV for diagnosing fibrosis as F4 were 26.2 % and 29.3 %, with 95.0 % and 90.0 % sensitivity and 72.9 % and 85.4 % specificity, respectively. Conclusion: The liver parenchymal iodine density on the equilibrium phase and the CT-ECV can be useful for predicting a high stage of liver fibrosis.
AB - Purpose: To elucidate the diagnostic ability of liver fibrosis using (1) liver parenchymal iodine density on equilibrium computed tomographic imaging and (2) extracellular volume (ECV) measured by dual-layer spectral detector CT. Methods: From April 2018 to June 2019, 68 patients [mean age, 62 years; 39 males, 29 females] underwent dynamic contrast-enhanced CT by a dual-layer spectral detector CT system before liver transplantation or liver resection. The iodine densities of liver parenchyma (I liver) and aorta (I aorta) were independently measured by two radiologists at the equilibrium phase. The iodine-density ratio (I-ratio) (I liver/ I aorta) and the CT-ECV were calculated. Spearman's rank correlation coefficient was used to analyze the relationship between the I-ratio or the CT-ECV and the fibrosis stage. A receiver operating characteristic (ROC) curve analysis was performed to determine the accuracy of the I-ratio and the CT-ECV for discriminating fibrosis stages. Results: For both readers, the I-ratio and the CT-ECV increased significantly as the fibrosis stage advanced (I-ratio: rho = 0.380 and 0.443, p < 0.01; CT-ECV: rho = 0.423 and 0.469, p < 0.01). The CT-ECV showed better diagnostic accuracy for staging fibrosis, and the area under the ROC curve values for discriminating F4 stage were 0.884 and 0.925. The two readers' cutoff values of the CT-ECV for diagnosing fibrosis as F4 were 26.2 % and 29.3 %, with 95.0 % and 90.0 % sensitivity and 72.9 % and 85.4 % specificity, respectively. Conclusion: The liver parenchymal iodine density on the equilibrium phase and the CT-ECV can be useful for predicting a high stage of liver fibrosis.
UR - http://www.scopus.com/inward/record.url?scp=85100372777&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85100372777&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2021.109575
DO - 10.1016/j.ejrad.2021.109575
M3 - Article
C2 - 33548853
AN - SCOPUS:85100372777
SN - 0720-048X
VL - 136
JO - European Journal of Radiology
JF - European Journal of Radiology
M1 - 109575
ER -