T1 - Multifunctional flow-injection biosensor for the simultaneous measurement of creatinine, glucose, and urea
AU - Rui, Chang Sheng
AU - Ogawa, Hiroaki I.
AU - Sonomoto, Kenji
AU - Kato, Yasuhiko
AU - Sonomoto, Kenji
N1 - Funding Information:
Acknowledgment. This work was a part of the study supported by a Grant-in-Aid for Scientific Research from the Ministry of Education, Science, and Culture of Japan.
PY - 1993/1
Y1 - 1993/1
N2 - An amperometric flow-injection biosensor system was developed for the simultaneous measurement of creatinine, glucose, and urea, with a single sample injection and one detector. The principle for the amperometric detection of urea and creatinine was based on coupled reactions of three sequentially aligned enzyme reactors, urease or creatinine deiminase/glutamate dehydrogenase/L-glutamate oxidase. Inclusion of a split point and two confluence points between the injector and detector (oxygen electrode) resulted in a flow-injection system composed of three channels. Triple peak recording was obtained by putting two delay coils of different lengths at the channels involving urease and glucose oxidase. The system gave linear calibrations for creatinine, glucose, and urea in the ranges of 0.2–5, 0.2–10, and 0.5–20mM, respectively. The assay procedure was simple and one run was completed within 4 min. The system was reproducible within 5–8% of relative standard deviation.
AB - An amperometric flow-injection biosensor system was developed for the simultaneous measurement of creatinine, glucose, and urea, with a single sample injection and one detector. The principle for the amperometric detection of urea and creatinine was based on coupled reactions of three sequentially aligned enzyme reactors, urease or creatinine deiminase/glutamate dehydrogenase/L-glutamate oxidase. Inclusion of a split point and two confluence points between the injector and detector (oxygen electrode) resulted in a flow-injection system composed of three channels. Triple peak recording was obtained by putting two delay coils of different lengths at the channels involving urease and glucose oxidase. The system gave linear calibrations for creatinine, glucose, and urea in the ranges of 0.2–5, 0.2–10, and 0.5–20mM, respectively. The assay procedure was simple and one run was completed within 4 min. The system was reproducible within 5–8% of relative standard deviation.
UR - http://www.scopus.com/inward/record.url?scp=0000071223&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0000071223&partnerID=8YFLogxK
U2 - 10.1271/bbb.57.191
DO - 10.1271/bbb.57.191
M3 - Article
AN - SCOPUS:0000071223
SN - 0916-8451
VL - 57
SP - 191
EP - 194
JO - Bioscience, Biotechnology and Biochemistry
JF - Bioscience, Biotechnology and Biochemistry
IS - 2
ER -