TY - JOUR
T1 - Liquid biopsy with multiplex ligation-dependent probe amplification targeting cell-free tumor DNA in cerebrospinal fluid from patients with adult diffuse glioma
AU - Otsuji, Ryosuke
AU - Fujioka, Yutaka
AU - Hata, Nobuhiro
AU - Kuga, Daisuke
AU - Sangatsuda, Yuhei
AU - Takigawa, Kosuke
AU - Funakoshi, Yusuke
AU - Sako, Aki
AU - Yamamoto, Hidetaka
AU - Nakamizo, Akira
AU - Mizoguchi, Masahiro
AU - Yoshimoto, Koji
N1 - Publisher Copyright:
© 2022 The Author(s). Published by Oxford University Press, the Society for Neuro-Oncology and the European Association of Neuro-Oncology.
PY - 2023/1/1
Y1 - 2023/1/1
N2 - Background: Copy number alterations (CNAs) are common in diffuse gliomas and have been shown to have diagnostic significance. While liquid biopsy for diffuse glioma has been widely investigated, techniques for detecting CNAs are currently limited to methods such as next-generation sequencing. Multiplex ligation-dependent probe amplification (MLPA) is an established method for copy number analysis in pre-specified loci. In this study, we investigated whether CNAs could be detected by MLPA using patients' cerebrospinal fluid (CSF). Methods: Twenty-five cases of adult diffuse glioma with CNAs were selected. Cell-free DNA (cfDNA) was extracted from the CSF, and DNA sizes and concentrations were recorded. Twelve samples, which had appropriate DNA sizes and concentrations, were subsequently used for analysis. Results: MLPA could be successfully performed in all 12 cases, and the detected CNAs were concordant with those detected using tumor tissues. Cases with epidermal growth factor receptor (EGFR) amplification, combination of gain of chromosome 7 and loss of chromosome 10, platelet-derived growth factor receptor alpha amplification, cyclin-dependent kinase 4 amplification, and cyclin-dependent kinase inhibitor 2A (CDKN2A) homozygous deletion were clearly distinguished from those with normal copy numbers. Moreover, EGFR variant III was accurately detected based on CNA. Conclusions: Thus, our results demonstrate that copy number analysis can be successfully performed by MLPA of cfDNA extracted from the CSF of patients with diffuse glioma.
AB - Background: Copy number alterations (CNAs) are common in diffuse gliomas and have been shown to have diagnostic significance. While liquid biopsy for diffuse glioma has been widely investigated, techniques for detecting CNAs are currently limited to methods such as next-generation sequencing. Multiplex ligation-dependent probe amplification (MLPA) is an established method for copy number analysis in pre-specified loci. In this study, we investigated whether CNAs could be detected by MLPA using patients' cerebrospinal fluid (CSF). Methods: Twenty-five cases of adult diffuse glioma with CNAs were selected. Cell-free DNA (cfDNA) was extracted from the CSF, and DNA sizes and concentrations were recorded. Twelve samples, which had appropriate DNA sizes and concentrations, were subsequently used for analysis. Results: MLPA could be successfully performed in all 12 cases, and the detected CNAs were concordant with those detected using tumor tissues. Cases with epidermal growth factor receptor (EGFR) amplification, combination of gain of chromosome 7 and loss of chromosome 10, platelet-derived growth factor receptor alpha amplification, cyclin-dependent kinase 4 amplification, and cyclin-dependent kinase inhibitor 2A (CDKN2A) homozygous deletion were clearly distinguished from those with normal copy numbers. Moreover, EGFR variant III was accurately detected based on CNA. Conclusions: Thus, our results demonstrate that copy number analysis can be successfully performed by MLPA of cfDNA extracted from the CSF of patients with diffuse glioma.
UR - http://www.scopus.com/inward/record.url?scp=85161023646&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85161023646&partnerID=8YFLogxK
U2 - 10.1093/noajnl/vdac178
DO - 10.1093/noajnl/vdac178
M3 - Article
AN - SCOPUS:85161023646
SN - 2632-2498
VL - 5
JO - Neuro-Oncology Advances
JF - Neuro-Oncology Advances
IS - 1
M1 - vdac178
ER -