Purpose: It is unclear whether experience at high-volume institute improves the treatment quality of prostate seed implantation. The aim of this study was to evaluate the effect of institutional experience on postimplant dosimetric parameters in a nationwide prospective cohort study. Methods: From July 2005 to June 2007, 2354 patients were registered in the Japanese Prostate Cancer Outcome Study of Permanent I‑125 Seed Implantation (J-POPS), and 1126 patients treated with seed implantation alone were evaluated. As a surrogate for institutional experience, we classified the J‑POPS institutions as high-volume (patient accrual volume was ≥120 patients per institution) or low-volume institutions (patient accrual volume was <120 patients per institution). To compare treatment quality between institutions, we evaluated the postimplant dosimetric parameters including D90, V100/150 (prostatic dose parameters), UD5/90, U200 (urethral dose parameters), and rectum R100/150 (rectal dose parameters). Results: In the 5 high-volume institutions (n = 601 patients), most of the patients were treated with >144 Gy of D90, whereas in the 20 low-volume institutions (n = 525) some of the patients were treated with <144 Gy. The V100 of most of the high-volume institution patients were >90%, whereas in the low-volume institutions a considerable percentage of patients showed lower V100. Although there was no correlation between D90 and rectal dose parameters, UD90 had a moderate positive correlation with D90 in both the high- and low-volume institutions. U200 varied more widely in the low-volume institutions. Conclusions: Our findings indicate that the institutional patient accrual volume is associated with the treatment quality of I‑125 prostate seed implantation.
| 本文言語 | 英語 |
|---|---|
| ページ(範囲) | 412-419 |
| ページ数 | 8 |
| ジャーナル | Strahlentherapie und Onkologie |
| 巻 | 195 |
| 号 | 5 |
| DOI | |
| 出版ステータス | 出版済み - 5月 1 2019 |
| 外部発表 | はい |
UN SDG
この成果は、次の持続可能な開発目標に貢献しています
-
SDG 3 すべての人に健康と福祉を
!!!All Science Journal Classification (ASJC) codes
- 放射線学、核医学およびイメージング
- 腫瘍学
フィンガープリント
「Institutional patient accrual volume and the treatment quality of I‑125 prostate seed implantation in a Japanese nationwide prospective cohort study」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS