Grading of gliomas using 3D CEST imaging with compressed sensing and sensitivity encoding

Tatsuhiro Wada, Osamu Togao, Chiaki Tokunaga, Masahiro Oga, Kazufumi Kikuchi, Koji Yamashita, Hidetaka Yamamoto, Masami Yoneyama, Koji Kobayashi, Toyoyuki Kato, Kousei Ishigami, Hidetake Yabuuchi

研究成果: ジャーナルへの寄稿学術誌査読

3 被引用数 (Scopus)

抄録

Purpose: We evaluated the usefulness of three-dimensional (3D) chemical exchange saturation transfer (CEST) imaging with compressed sensing and sensitivity encoding (CS-SENSE) for differentiating low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Methods: We evaluated 28 patients (mean age 51.0 ± 13.9 years, 13 males, 15 females) including 12 with LGGs and 16 with HGGs, all acquired using a 3 T magnetic resonance (MR) scanner. Nine slices were acquired for 3D CEST imaging, and one slice was acquired for two-dimensional (2D) CEST imaging. Two radiological technologists each drew a region of interest (ROI) surrounding the high-signal-intensity area(s) on the fluid-attenuated inversion recovery image of each patient. We compared the magnetization transfer ratio asymmetry (MTRasym) at 3.5 ppm in the tumors among the (i) single-slice 2D CEST imaging (“2D”), (ii) all tumor slices of the 3D CEST imaging (3Dall), and (iii) a representative tumor slice of 3D CEST imaging (maximum signal intensity [3Dmax]). The relationship between the MTRasym at 3.5 ppm values measured by these three methods and the Ki-67 labeling index (LI) of the tumors was assessed. Diagnostic performance was evaluated with a receiver operating characteristic analysis. The Ki-67LI and MTRasym at 3.5 ppm values were compared between the LGGs and HGGs. Results: A moderate positive correlation between the MTRasym at 3.5 ppm and the Ki-67LI was observed with all three methods. All methods proved a significantly larger MTRasym at 3.5 ppm for the HGGs compared to the LGGs. All methods showed equivalent diagnostic performance. The signal intensity varied depending on the slice position in each case. Conclusions: The 3D CEST imaging provided the MTRasym at 3.5 ppm for each slice cross-section; its diagnostic performance was also equivalent to that of 2D CEST imaging.

本文言語英語
論文番号110654
ジャーナルEuropean Journal of Radiology
158
DOI
出版ステータス出版済み - 1月 2023

!!!All Science Journal Classification (ASJC) codes

  • 放射線学、核医学およびイメージング

フィンガープリント

「Grading of gliomas using 3D CEST imaging with compressed sensing and sensitivity encoding」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル