Frequency characteristics of pressure transducer kits with inserted pressure-resistant extension tubes

  • Shigeki Fujiwara
  • , Satoshi Mori
  • , Keiichi Tachihara
  • , Takeshi Yamamoto
  • , Chizuko Yokoe
  • , Uno Imaizumi
  • , Yoshinari Morimoto
  • , Yoichiro Miki
  • , Izumi Toyoguchi
  • , Kazu ichi Yoshida
  • , Takeshi Yokoyama

研究成果: ジャーナルへの寄稿学術誌査読

抄録

The accurate monitoring of arterial blood pressure is important for cardiovascular management. However, the frequency characteristics of pressure transducer kits are influenced by the length of the pressure-resistant tube. To date, there have been few studies addressing the frequency characteristics of pressure transducer kits with inserted pressure-resistant extension tubes (pressure-resistant extension tube (ET) circuits). In this study, we examine ET circuits from the viewpoint of the frequency characteristics of pressure transducer kits. DT4812J transducer kits (length 150 cm; Argon Medical Devices, TX, USA) were used. Three original ET circuits were prepared, with the pressure-resistant tube of the DT4812J being extended with a 30-cm length of pressure-resistant tube (180ET circuit), a 60-cm length of pressure-resistant tube (210ET circuit), and a 90-cm length of pressure-resistant tube (240ET circuit). Each of these circuits was evaluated as part of this study. The natural frequency of the original DT4812J circuit was 45.90 Hz while the damping coefficient was 0.160. For the 180 ET circuit, the natural frequency and damping coefficient were 36.4 Hz and 0.162, respectively. For the ET210 circuit, the natural frequency and damping coefficient were 30.3 Hz and 0.175, respectively. For the ET210 circuit, the natural frequency and damping coefficient were 25.3 Hz and 0.180, respectively. As a result of extending the circuit, it was found that the natural frequency decreased drastically, while the damping coefficient increased slightly. When the extension of a pressure transducer kit is required, we should pay careful attention to the major decrease in the natural frequency, which may influence the pressure monitoring.

本文言語英語
ページ(範囲)371-380
ページ数10
ジャーナルJournal of Clinical Monitoring and Computing
31
2
DOI
出版ステータス出版済み - 4月 1 2017

!!!All Science Journal Classification (ASJC) codes

  • 健康情報学
  • 集中医療医学
  • 麻酔学および疼痛医療

フィンガープリント

「Frequency characteristics of pressure transducer kits with inserted pressure-resistant extension tubes」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル