TY - JOUR
T1 - Estimation of organ and effective doses in High-Resolution Cone-Beam Computed Tomography (HR-CBCT) during cerebral angiography
AU - Miyazaki, Hitoshi
AU - Fujibuchi, Toshioh
AU - Han, Donghee
AU - Oura, Koji
AU - Kosoegawa, Takahiro
AU - Hamasaki, Hiroshi
AU - Yoshikawa, Hideki
AU - Arimura, Koichi
AU - Kato, Toyoyuki
AU - Ishigami, Kousei
AU - Yamashita, Koji
N1 - Publisher Copyright:
© The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics 2025.
PY - 2026/3
Y1 - 2026/3
N2 - High-resolution cone-beam computed tomography (HR-CBCT) during cerebral angiography raises concerns regarding high radiation exposure in exchange for high spatial resolution, but detailed dose assessments are lacking. This study aimed to accurately estimate organ dose (OD) and effective dose (ED) for HR-CBCT using the NCIRF Monte Carlo software, which incorporates projection-specific variations in X-ray output, and to derive dose conversion coefficients for clinical application. Four sites prone to cerebral aneurysms were scanned using a phantom, and exposure parameters were recorded for each projection angle. OD and ED were calculated using NCIRF. Simulation accuracy was validated by comparing lens doses measured with radiophotoluminescence glass dosimeters, and the results were compared with a conventional method that ignores projection-specific dose variations. The maximum brain OD was 46.2 mGy for males and 61.7 mGy for females. ED ranged from 0.70 to 0.89 mSv for males and 0.86–1.11 mSv for females. The relative difference between simulated and measured lens doses was less than 6.0%, demonstrating good agreement. The proposed method reduced lens dose error by approximately 20% compared to the conventional method. Conversion coefficients were calculated for each site and sex to estimate OD and ED from the air kerma-area product. This study demonstrated that dynamic Monte Carlo simulation incorporating projection-specific exposure variations can provide highly accurate dose estimations for HR-CBCT. The derived conversion coefficients offer a practical tool that can support optimization of patient radiation protection in clinical settings using similar equipment and protocols.
AB - High-resolution cone-beam computed tomography (HR-CBCT) during cerebral angiography raises concerns regarding high radiation exposure in exchange for high spatial resolution, but detailed dose assessments are lacking. This study aimed to accurately estimate organ dose (OD) and effective dose (ED) for HR-CBCT using the NCIRF Monte Carlo software, which incorporates projection-specific variations in X-ray output, and to derive dose conversion coefficients for clinical application. Four sites prone to cerebral aneurysms were scanned using a phantom, and exposure parameters were recorded for each projection angle. OD and ED were calculated using NCIRF. Simulation accuracy was validated by comparing lens doses measured with radiophotoluminescence glass dosimeters, and the results were compared with a conventional method that ignores projection-specific dose variations. The maximum brain OD was 46.2 mGy for males and 61.7 mGy for females. ED ranged from 0.70 to 0.89 mSv for males and 0.86–1.11 mSv for females. The relative difference between simulated and measured lens doses was less than 6.0%, demonstrating good agreement. The proposed method reduced lens dose error by approximately 20% compared to the conventional method. Conversion coefficients were calculated for each site and sex to estimate OD and ED from the air kerma-area product. This study demonstrated that dynamic Monte Carlo simulation incorporating projection-specific exposure variations can provide highly accurate dose estimations for HR-CBCT. The derived conversion coefficients offer a practical tool that can support optimization of patient radiation protection in clinical settings using similar equipment and protocols.
KW - Effective dose
KW - HR-CBCT
KW - Monte carlo simulation
KW - NCIRF
KW - Organ dose
UR - https://www.scopus.com/pages/publications/105020315031
UR - https://www.scopus.com/pages/publications/105020315031#tab=citedBy
U2 - 10.1007/s12194-025-00982-3
DO - 10.1007/s12194-025-00982-3
M3 - Article
C2 - 41171492
AN - SCOPUS:105020315031
SN - 1865-0333
VL - 19
SP - 114
EP - 124
JO - Radiological physics and technology
JF - Radiological physics and technology
IS - 1
ER -