N2 - The durability of a water electrolysis cell against wind power voltage fluctuations was evaluated by developing an accelerated potential fluctuation test protocol based on wind power voltage fluctuations over an actual 24 h period of operation. Accelerating potential protocol tests corresponding to 160 d of actual operation were performed. The current loss during the test is mostly recovered if rest time was included during the operation. Reversible loss is most likely related to gas stagnation, suppression of oxygen reduction reaction activity owing to the formation less active Ir(V) species, and suppression of gas evolution owing to the increased hydrophilic surface. This irreversible loss can be attributed to the dissolution of IrO2 and the loss of Nafion® ionomer. Even though the potential fluctuation itself was not a problem if the lowest potential was 1.0 V, the upper limit of the potential was rather problematic. When the upper potential is increased to 2.3 V, the oxidation of IrO2 is enhanced, leading to the partial dissolution of IrO2, followed by the formation of a dense structure, a decrease in the oxygen evolution reaction activity, and an increase in the surface hydrophilicity.
AB - The durability of a water electrolysis cell against wind power voltage fluctuations was evaluated by developing an accelerated potential fluctuation test protocol based on wind power voltage fluctuations over an actual 24 h period of operation. Accelerating potential protocol tests corresponding to 160 d of actual operation were performed. The current loss during the test is mostly recovered if rest time was included during the operation. Reversible loss is most likely related to gas stagnation, suppression of oxygen reduction reaction activity owing to the formation less active Ir(V) species, and suppression of gas evolution owing to the increased hydrophilic surface. This irreversible loss can be attributed to the dissolution of IrO2 and the loss of Nafion® ionomer. Even though the potential fluctuation itself was not a problem if the lowest potential was 1.0 V, the upper limit of the potential was rather problematic. When the upper potential is increased to 2.3 V, the oxidation of IrO2 is enhanced, leading to the partial dissolution of IrO2, followed by the formation of a dense structure, a decrease in the oxygen evolution reaction activity, and an increase in the surface hydrophilicity.
UR - http://www.scopus.com/inward/record.url?scp=85148771868&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85148771868&partnerID=8YFLogxK
U2 - 10.1016/j.jpowsour.2023.232826
DO - 10.1016/j.jpowsour.2023.232826
M3 - Article
AN - SCOPUS:85148771868
SN - 0378-7753
VL - 564
JO - Journal of Power Sources
JF - Journal of Power Sources
M1 - 232826
ER -