メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

Continuous monitoring of aluminum corrosion process in deaerated water

  • Katsuya Ishii
  • , Ryota Ozaki
  • , Kenji Kaneko
  • , Hisaaki Fukushima
  • , Masataka Masuda

    研究成果: ジャーナルへの寄稿 › 学術誌 › 査読

    35   !!Link opens in a new tab 被引用数 (Scopus)

    抄録

    A device was developed for the continuous measurement of the open circuit corrosion rate of aluminum in deaerated water from hydrogen pressure, resulted from the cathodic reaction. Corrosion rate of aluminum coated by the passive oxide film was examined with respect to the corrosion phenomena using this device. From the results, it was found that the corrosion rate was dependent not only on the deterioration of the film, but also on the formation of pits and of corrosion products on the film. Furthermore, the deterioration of the film was independent on the pH of the water. The pits were most probably formed by the evolution of hydrogen gas at the cathode underneath the film followed by the formation of Al (OH)4-.

    本文言語英語
    ページ(範囲)2581-2601
    ページ数21
    ジャーナルCorrosion Science
    巻49
    号6
    DOI
    出版ステータス出版済み - 6月 2007

    !!!All Science Journal Classification (ASJC) codes

    • 化学一般
    • 化学工学一般
    • 材料科学一般

    フィンガープリント

    「Continuous monitoring of aluminum corrosion process in deaerated water」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。