TY - JOUR
T1 - CALCULATION OF TEMPERATURE OF VENTILATION AIR WITH VARYING AIR TEMPERATURE AT THE ENTRANCE.
AU - UCHINO, KEN ICHI
AU - INOUE, MASAHIRO
AU - YANAGIMOTO, TAKEICHI
N1 - Copyright:
Copyright 2020 Elsevier B.V., All rights reserved.
PY - 1982
Y1 - 1982
N2 - IN THE PRESENT PAPER THE EFFECT OF VARIATION OF THE AIR TEMPERATURE AT THE ENTRANCE ON THE AIR TEMPERATURE ALONG THE ROADWAY IS THEORETICALLY ANALYZED. A GENERAL EXPRESSION IS FIRST OBTAINED FOR THE TEMPERATURE ALONG THE ROADWAY WHEN THE AIR TEMPERATURE AT THE ENTRANCE CHANGES ARBITRARILY. THEN NUMERICAL VALUES OF THAT EQUATION ARE CALCULATED FOR TWO PRACTICAL CASES: SINUSOIDAL AND SUDDEN CHANGES OF THE TEMPERATURE AT THE ENTRANCE. RESULTS OF THE DISCUSSION ARE AS FOLLOWS; (A) IN THE CASE OF THE SINUSOIDAL CHANGE THE TEMPERATURE OF VENTILATION AIR SHOWS A TRANSIENT STATE AT THE BEGINNING OF VENTILATION, BUT THEN REACHES SOME SINUSOIDAL STATE OF VARIATION WITH THE AMPLITUDE REDUCED AND THE PHASE DELAYED AS THE DISTANCE FROM THE ENTRANCE INCREASES. (B) THE EFFECT OF A SUDDEN AIR TEMPERATURE CHANGE AT THE ENTRANCE IS INSTANTANEOUSON THE TEMPERATURE OF VENTILATION AIR AT A SHORT DISTANCE FROM THE ENTRANCE AND IS GRADUAL AS THE DISTANCE INCREASES. TWO PRACTICAL APPROXIMATE EQUATIONS FOR THIS CASE ARE PROPOSED. IN JAPANESE WITH ENGLISH ABSTRACT.
AB - IN THE PRESENT PAPER THE EFFECT OF VARIATION OF THE AIR TEMPERATURE AT THE ENTRANCE ON THE AIR TEMPERATURE ALONG THE ROADWAY IS THEORETICALLY ANALYZED. A GENERAL EXPRESSION IS FIRST OBTAINED FOR THE TEMPERATURE ALONG THE ROADWAY WHEN THE AIR TEMPERATURE AT THE ENTRANCE CHANGES ARBITRARILY. THEN NUMERICAL VALUES OF THAT EQUATION ARE CALCULATED FOR TWO PRACTICAL CASES: SINUSOIDAL AND SUDDEN CHANGES OF THE TEMPERATURE AT THE ENTRANCE. RESULTS OF THE DISCUSSION ARE AS FOLLOWS; (A) IN THE CASE OF THE SINUSOIDAL CHANGE THE TEMPERATURE OF VENTILATION AIR SHOWS A TRANSIENT STATE AT THE BEGINNING OF VENTILATION, BUT THEN REACHES SOME SINUSOIDAL STATE OF VARIATION WITH THE AMPLITUDE REDUCED AND THE PHASE DELAYED AS THE DISTANCE FROM THE ENTRANCE INCREASES. (B) THE EFFECT OF A SUDDEN AIR TEMPERATURE CHANGE AT THE ENTRANCE IS INSTANTANEOUSON THE TEMPERATURE OF VENTILATION AIR AT A SHORT DISTANCE FROM THE ENTRANCE AND IS GRADUAL AS THE DISTANCE INCREASES. TWO PRACTICAL APPROXIMATE EQUATIONS FOR THIS CASE ARE PROPOSED. IN JAPANESE WITH ENGLISH ABSTRACT.
UR - http://www.scopus.com/inward/record.url?scp=0020127384&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0020127384&partnerID=8YFLogxK
U2 - 10.2473/shigentosozai1953.98.1131_405
DO - 10.2473/shigentosozai1953.98.1131_405
M3 - Article
AN - SCOPUS:0020127384
SN - 0369-4194
VL - V 98
SP - 405
EP - 410
JO - NIPPON KOGYO KAISHI
JF - NIPPON KOGYO KAISHI
IS - N 1131
ER -