T1 - Assessment of the Accuracy in Measuring the Enamel Thickness of Maxillary Incisors with Optical Coherence Tomography
AU - Miyagi, Hiroshi
AU - Oki, Kyosuke
AU - Tsukiyama, Yoshihiro
AU - Ayukawa, Yasunori
AU - Koyano, Kiyoshi
N1 - Funding Information:
The SS-OCT system used in this study was provided by Panasonic Healthcare, Co., Ltd., Japan, and there were no conflicts of interest. We are deeply indebted to Panasonic Healthcare, Co., Ltd., for cooperating in this study.
Publisher Copyright:
© 2022 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2022/7
Y1 - 2022/7
N2 - Although the clinical assessment of enamel thickness is important, hardly any tools exist for accurate measurements. The purpose of this study was to verify the precision of enamel thickness measurements using swept-source optical coherence tomography (SS-OCT). Human extracted maxillary central and lateral incisors were used as specimens. Twenty-eight sites were measured in each specimen. The optical path length (OPL) at each measurement site was measured on the OCT images, and enamel thickness (e1) was calculated by dividing OPL by the mean refractive index of enamel, 1.63. The specimens were then sectioned, and a light microscope was used to measure enamel thickness (e2). e1 and e2 were then compared. Measurement errors between e1 and e2 for the central and lateral incisors were 0.04 (0.02; 0.06) mm and 0.04 (0.02; 0.07) mm [median value: (25%, 75% percentile)], respectively. No significant differences between measurement sites were noted for measurement errors between e1 and e2. These results demonstrate that OCT can be used for noninvasive, accurate measurements of enamel thickness.
AB - Although the clinical assessment of enamel thickness is important, hardly any tools exist for accurate measurements. The purpose of this study was to verify the precision of enamel thickness measurements using swept-source optical coherence tomography (SS-OCT). Human extracted maxillary central and lateral incisors were used as specimens. Twenty-eight sites were measured in each specimen. The optical path length (OPL) at each measurement site was measured on the OCT images, and enamel thickness (e1) was calculated by dividing OPL by the mean refractive index of enamel, 1.63. The specimens were then sectioned, and a light microscope was used to measure enamel thickness (e2). e1 and e2 were then compared. Measurement errors between e1 and e2 for the central and lateral incisors were 0.04 (0.02; 0.06) mm and 0.04 (0.02; 0.07) mm [median value: (25%, 75% percentile)], respectively. No significant differences between measurement sites were noted for measurement errors between e1 and e2. These results demonstrate that OCT can be used for noninvasive, accurate measurements of enamel thickness.
UR - http://www.scopus.com/inward/record.url?scp=85133858030&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85133858030&partnerID=8YFLogxK
U2 - 10.3390/diagnostics12071634
DO - 10.3390/diagnostics12071634
M3 - Article
AN - SCOPUS:85133858030
SN - 2075-4418
VL - 12
JO - Diagnostics
JF - Diagnostics
IS - 7
M1 - 1634
ER -