抄録
Temporal and spatial variations in anthropogenic water vapor (AWV) emissions and anthropogenic heat (AH) in Tokyo were estimated using data from a geographic information system (GIS) and an energy-consumption database. The maximum value of AWV exceeded 500 W m-2 in summer in central Tokyo. Estimations of AWV were validated with field-measured data. The estimated and measured data agreed well, indicating that anthropogenic sources such as district cooling systems release large amounts of water vapor into the atmosphere.
本文言語 | 英語 |
---|---|
論文番号 | W11424 |
ジャーナル | Water Resources Research |
巻 | 44 |
号 | 11 |
DOI | |
出版ステータス | 出版済み - 11月 2008 |
!!!All Science Journal Classification (ASJC) codes
- 水の科学と技術