TY - JOUR
T1 - An investigation of flow fields around flanged diffusers using CFD
AU - Abe, Ken Ichi
AU - Ohya, Yuji
N1 - Funding Information:
This work was supported by four Grant-in-Aids for Scientific Research, No. 14205139, sponsored by the Ministry of Education, Culture, Sports, Science and Technology, Japan, for Environment Protection Research sponsored by Sumitomo Fund, for Fluid Machinery Research sponsored by Harada Memorial Fund and for the Program and Project for Education and Research of Kyushu University. It was also supported by a matching fund of the Ministry of Economy, Trade and Industry. KA wishes to express his appreciation to Professor M.A. Leschziner of Imperial College of Science, Technology and Medicine, London, UK for the support in using the STREAM code.
PY - 2004/3
Y1 - 2004/3
N2 - Numerical investigations are carried out for flow fields around flanged diffusers to develop small-type wind turbines under 1.5 kW. In the calculations, an advanced closure approximation is adopted, within the framework of non-linear eddy-viscosity modeling, which aims specifically at an improved representation of turbulence anisotropy. Comparison of the computed results with the corresponding experimental data shows that the present calculation has the capability of providing reasonable predictions for the present complex turbulent flows. Furthermore, by processing the computational results, the input-power coefficient is estimated under various conditions of diffuser opening angle and loading coefficient. It is shown that the performance of a flanged diffuser strongly depends on the loading coefficient as well as the opening angle because it greatly affects the nature of the separation appearing inside the diffuser. The present investigation suggests that the loading coefficient for the best performance of a flanged diffuser is considerably smaller than that for a bare wind turbine.
AB - Numerical investigations are carried out for flow fields around flanged diffusers to develop small-type wind turbines under 1.5 kW. In the calculations, an advanced closure approximation is adopted, within the framework of non-linear eddy-viscosity modeling, which aims specifically at an improved representation of turbulence anisotropy. Comparison of the computed results with the corresponding experimental data shows that the present calculation has the capability of providing reasonable predictions for the present complex turbulent flows. Furthermore, by processing the computational results, the input-power coefficient is estimated under various conditions of diffuser opening angle and loading coefficient. It is shown that the performance of a flanged diffuser strongly depends on the loading coefficient as well as the opening angle because it greatly affects the nature of the separation appearing inside the diffuser. The present investigation suggests that the loading coefficient for the best performance of a flanged diffuser is considerably smaller than that for a bare wind turbine.
UR - https://www.scopus.com/pages/publications/1542316240
UR - https://www.scopus.com/pages/publications/1542316240#tab=citedBy
U2 - 10.1016/j.jweia.2003.12.003
DO - 10.1016/j.jweia.2003.12.003
M3 - Article
AN - SCOPUS:1542316240
SN - 0167-6105
VL - 92
SP - 315
EP - 330
JO - Journal of Wind Engineering and Industrial Aerodynamics
JF - Journal of Wind Engineering and Industrial Aerodynamics
IS - 3-4
ER -