メインナビゲーションにスキップ 検索にスキップ メインコンテンツにスキップ

An application of CCD read-out technique to neutron distribution measurement using the self-activation method with a CsI scintillator plate

  • Akihiro Nohtomi
  • , Ryosuke Kurihara
  • , Hiroyuki Kinoshita
  • , Soichiro Honda
  • , Masaaki Tokunaga
  • , Heita Uno
  • , Kiyomitsu Shinsho
  • , Genichiro Wakabayashi
  • , Yusuke Koba
  • , Junichi Fukunaga
  • , Yoshiyuki Umezu
  • , Yasuhiko Nakamura
  • , Saiji Ohga

研究成果: ジャーナルへの寄稿 › 学術誌 › 査読

6   !!Link opens in a new tab 被引用数 (Scopus)

抄録

In our previous paper, the self-activation of an NaI scintillator had been successfully utilized for detecting photo-neutrons around a high-energy X-ray radiotherapy machine; individual optical pulses from the self-activated scintillator are read-out by photo sensors such as a photomultiplier tube (PMT). In the present work, preliminary observations have been performed in order to apply a direct CCD read-out technique to the self-activation method with a CsI scintillator plate using a Pu-Be source and a 10-MV linac. In conclusion, it has been revealed that the CCD read-out technique is applicable to neutron measurement around a high-energy X-ray radiotherapy machine with the self-activation of a CsI plate. Such application may provide a possibility of novel method for simple neutron dose-distribution measurement.

本文言語英語
ページ(範囲)21-23
ページ数3
ジャーナルNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
巻832
DOI
出版ステータス出版済み - 10月 1 2016

!!!All Science Journal Classification (ASJC) codes

  • 核物理学および高エネルギー物理学
  • 器械工学