抄録
The ASTRO-E Hard X-ray Detector utilized GSO/BGO well-type phoswich counters in compound-eye configuration [1], to achieve an extremely low background level of a few ×10-5 counts s-1cm-2keV-1. The GSO scintillators installed in the BGO active shield wells observes 30-600 keV photons, while silicon PIN diodes of 2 mm thick placed in front of each GSO crystal covers 10 - 60 keV photons with energy resolution of ∼3.5 keV FWHM. The design goals both of low background and high energy resolution in the hard X-ray bands were confirmed to be achieved through the preflight calibration experiments.
| 本文言語 | 英語 |
|---|---|
| ページ | 483-486 |
| ページ数 | 4 |
| 出版ステータス | 出版済み - 2001 |
| 外部発表 | はい |
| イベント | 2001 IEEE Nuclear Science Symposium Conference Record - San Diege, CA, 米国 継続期間: 11月 4 2001 → 11月 10 2001 |
その他
| その他 | 2001 IEEE Nuclear Science Symposium Conference Record |
|---|---|
| 国/地域 | 米国 |
| City | San Diege, CA |
| Period | 11/4/01 → 11/10/01 |
!!!All Science Journal Classification (ASJC) codes
- 放射線
- 核物理学および高エネルギー物理学
- 放射線学、核医学およびイメージング
フィンガープリント
「Achievements of the ASTRO-E hard X-ray detector development」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS