TY - JOUR
T1 - A straightforward DC-reversal method for the Thomson coefficient measurement
AU - Amagai, Yasutaka
AU - Shimazaki, Takeshi
AU - Okawa, Kenjiro
AU - Kawae, Tatsuya
AU - Fujiki, Hiroyuki
AU - Kaneko, Nobu Hisa
N1 - Publisher Copyright:
© 2022 Elsevier Ltd
PY - 2022/12
Y1 - 2022/12
N2 - DC reversal is a widely used technique for precise voltage measurement to remove DC offsets from the measurement signals. Herein, we propose a straightforward method using a DC reversal for the thermoelectric Thomson effect measurements. The proposed method allows the determination of Thomson coefficient from readily measurable quantities, that is, DC resistance, current, and the temperature changes caused by the Joule and Thomson effects, thereby removing the requirement of information on thermal conductivity and geometric values, which are required in a traditional DC-reversal method. Furthermore, this DC-based approach avoids typical complications experienced in recently developed AC-based methods, such as the absence of an AC current source or lock-in amplifier. The experimental results show that the Thomson coefficient of a fine Pt wire measured using the proposed method agrees well with a previously reported reference measurement with the expanded relative uncertainty of 6 %.
AB - DC reversal is a widely used technique for precise voltage measurement to remove DC offsets from the measurement signals. Herein, we propose a straightforward method using a DC reversal for the thermoelectric Thomson effect measurements. The proposed method allows the determination of Thomson coefficient from readily measurable quantities, that is, DC resistance, current, and the temperature changes caused by the Joule and Thomson effects, thereby removing the requirement of information on thermal conductivity and geometric values, which are required in a traditional DC-reversal method. Furthermore, this DC-based approach avoids typical complications experienced in recently developed AC-based methods, such as the absence of an AC current source or lock-in amplifier. The experimental results show that the Thomson coefficient of a fine Pt wire measured using the proposed method agrees well with a previously reported reference measurement with the expanded relative uncertainty of 6 %.
UR - http://www.scopus.com/inward/record.url?scp=85144021961&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85144021961&partnerID=8YFLogxK
U2 - 10.1016/j.measurement.2022.112205
DO - 10.1016/j.measurement.2022.112205
M3 - Article
AN - SCOPUS:85144021961
SN - 0263-2241
VL - 205
JO - Measurement: Journal of the International Measurement Confederation
JF - Measurement: Journal of the International Measurement Confederation
M1 - 112205
ER -