抄録
A thin plastic scintillator is used as a trigger counter of charged particle spectrometers. Since its Compton edge is not clear, it is difficult to check up the thin plastic scintillator counters with a standard gamma-ray source. In this paper, a simple method is proposed to determine the Compton edge and the energy resolution of the thin plastic scintillator by fitting the simulated spectrum to the measured. The simulated spectrum was made with a Monte Carlo program considering geometries of the plastic scintillator. This technique was examined with the plastic scintillator having thickness of 2mm to 10mm.
本文言語 | 英語 |
---|---|
ページ | 6/226-6/230 |
出版ステータス | 出版済み - 2000 |
イベント | 2000 IEEE Nuclear Science Symposium Conference Record - Lyon, フランス 継続期間: 10月 15 2000 → 10月 20 2000 |
その他
その他 | 2000 IEEE Nuclear Science Symposium Conference Record |
---|---|
国/地域 | フランス |
City | Lyon |
Period | 10/15/00 → 10/20/00 |
!!!All Science Journal Classification (ASJC) codes
- 放射線
- 核物理学および高エネルギー物理学
- 放射線学、核医学およびイメージング