TY - JOUR
T1 - Visualizing the Flow Patterns in an Expanding and Contracting Pulmonary Alveolated Duct Based on Microcomputed Tomography Images
AU - Sera, Toshihiro
AU - Kamiya, Naoki
AU - Fukushima, Taichi
AU - Tanaka, Gaku
N1 - Funding Information:
• JSPS KAKENHI (Grant No. JP19H04444; Funder ID: 10.13039/501100001691).
Publisher Copyright:
© 2021 BMJ Publishing Group. All rights reserved.
PY - 2021/7/1
Y1 - 2021/7/1
N2 - We visualized the flow patterns in an alveolated duct model with breathing-like expanding and contracting wall motions using particle image velocimetry, and then, we investigated the effect of acinar deformation on the flow patterns. We reconstructed a compliant, scaled-up model of an alveolated duct from synchrotron microcomputed tomography images of a mammalian lung. The alveolated duct did not include any bifurcation, and its entire surface was covered with alveoli. We embedded the alveolated duct in a sealed container that was filled with fluid. We oscillated the fluid in the duct and container simultaneously and independently to control the flow and duct volume. We examined the flow patterns in alveoli, with the Reynolds number (Re) at 0.03 or 0.22 and the acinar volume change at 0%, 20%, or 80%. At the same Re, the heterogeneous deformation induced different inspiration and expiration flow patterns, and the recirculating regions in alveoli changed during respiratory cycle. During a larger acinar deformation at Re = 0.03, the flow patterns tended to change from recirculating flow to radial flow during inspiration and vice versa during expiration. Additionally, the alveolar geometric characteristics, particularly the angle between the alveolar duct and mouth, affected these differences in flow patterns. At Re = 0.22, recirculating flow patterns tended to form during inspiration and expiration, regardless of the magnitude of the acinar deformation. Our in vitro experiments suggest that the alveolated flows with nonself-similar and heterogeneous wall motions may promote particle mixing and deposition.
AB - We visualized the flow patterns in an alveolated duct model with breathing-like expanding and contracting wall motions using particle image velocimetry, and then, we investigated the effect of acinar deformation on the flow patterns. We reconstructed a compliant, scaled-up model of an alveolated duct from synchrotron microcomputed tomography images of a mammalian lung. The alveolated duct did not include any bifurcation, and its entire surface was covered with alveoli. We embedded the alveolated duct in a sealed container that was filled with fluid. We oscillated the fluid in the duct and container simultaneously and independently to control the flow and duct volume. We examined the flow patterns in alveoli, with the Reynolds number (Re) at 0.03 or 0.22 and the acinar volume change at 0%, 20%, or 80%. At the same Re, the heterogeneous deformation induced different inspiration and expiration flow patterns, and the recirculating regions in alveoli changed during respiratory cycle. During a larger acinar deformation at Re = 0.03, the flow patterns tended to change from recirculating flow to radial flow during inspiration and vice versa during expiration. Additionally, the alveolar geometric characteristics, particularly the angle between the alveolar duct and mouth, affected these differences in flow patterns. At Re = 0.22, recirculating flow patterns tended to form during inspiration and expiration, regardless of the magnitude of the acinar deformation. Our in vitro experiments suggest that the alveolated flows with nonself-similar and heterogeneous wall motions may promote particle mixing and deposition.
UR - http://www.scopus.com/inward/record.url?scp=85103255521&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85103255521&partnerID=8YFLogxK
U2 - 10.1115/1.4050285
DO - 10.1115/1.4050285
M3 - Article
C2 - 33625506
AN - SCOPUS:85103255521
SN - 0148-0731
VL - 143
JO - Journal of Biomechanical Engineering
JF - Journal of Biomechanical Engineering
IS - 7
M1 - 074501
ER -