Skip to main navigation Skip to search Skip to main content

Verification of AVF Stenosis Using Luminance Conversion by Non-contact Measurement Method

  • Takunori Shimazaki
  • , Rumi Iwai
  • , Jaakko Hyry
  • , Yoshifumi Kawakubo
  • , Masashi Fukuhara
  • , Hiroki Aono
  • , Shingo Ata
  • , Takeshi Yokoyama
  • , Daisuke Anzai

Research output: Chapter in Book/Report/Conference proceeding › Conference contribution

Abstract

Hemodialysis therapy is an extracorporeal circulatory therapy that substitutes kidney function. At the beginning of therapy, special vessels called arterio-venous fistula (AVF) should be created, which puncture the dilated veins and allow for stable treatment. However, as they are prone to stenosis, a stethoscope is usually used to confirm the procedure before treatment. Although this method is simple and reliable, there are several critical issues to be resolved, such as missed stenosis sounds and difficulties in quantification. In our previous study, we proposed a new noncontact method to quantitatively confirm the AVF state using optical technology. In this study, the same method was used to represent the process from normal state to intense stenosis state in one hemodialysis patient using luminance and grayscale transformation to express the state of blood flow in colour, whose feasibility was verified through multiple comparison tests with ultrasound equipment. The results showed that in the multiple comparison test with Honest Significant Difference, all pairs without significant differences; however, there was a predominant difference between normal and intense stenosis on June 29 (II) and July 25(V)(p=0.038). On July 20, when mild stenosis was confirmed by ultrasound equipment findings, stenosis could be determined visually by the luminance and tone conversion. In the quartile evaluation by measurement date, the difference between the first and third quartiles was large on March 7 and June 29, and gradually decreased from June 6. This was considered to reflect the increase in internal pressure with the progression of stenosis and the suppression of venous wall pulsation due to the progression of vessel wall elongation. These results indicated that this method has the potential to visualise the stenosis site.

Original languageEnglish
Title of host publication2024 18th International Symposium on Medical Information and Communication Technology, ISMICT 2024
PublisherIEEE Computer Society
Pages74-77
Number of pages4
ISBN (Electronic)9798350353280
DOIs
Publication statusPublished - 2024
Event18th International Symposium on Medical Information and Communication Technology, ISMICT 2024 - London, United Kingdom
Duration: May 15 2024 → May 17 2024

Publication series

NameInternational Symposium on Medical Information and Communication Technology, ISMICT
ISSN (Print)2326-828X
ISSN (Electronic)2326-8301

Conference

Conference18th International Symposium on Medical Information and Communication Technology, ISMICT 2024
Country/TerritoryUnited Kingdom
CityLondon
Period5/15/24 → 5/17/24

All Science Journal Classification (ASJC) codes

  • Computer Networks and Communications
  • Information Systems
  • Health Informatics
  • Health Information Management

Fingerprint

Dive into the research topics of 'Verification of AVF Stenosis Using Luminance Conversion by Non-contact Measurement Method'. Together they form a unique fingerprint.

Cite this