TY - JOUR
T1 - Usefulness of the opposite direction for Stenvers' method
AU - Maruyama, Hirotoshi
AU - Ideguchi, Tadamitsu
AU - Ohura, Hiroki
AU - Azuma, Toshiya
AU - Orita, Shinichi
AU - Amano, Kazuhiro
AU - Higashida, Yoshiharu
PY - 2003/7
Y1 - 2003/7
N2 - In otorthinolaryngology, Stenvers' method is employed in radiography of the pyramid (internal acoustic meatus and semicircular canals). However, in cases of dizziness, where the prone position is difficult to achieve, we occasionally use the opposite Stenvers' method instead of the conventional one. This makes it possible to perform radiography with the patient in the supine position. Compared with the conventional Stenvers' method, the problems of this method were increases not only in the rate of magnification but also in lens dose. In this study, we evaluated these problems by employing computed tomography (CT) and a glass dosimeter with phantom as well as by clinical evaluation. The results showed no statistically significant difference between Stenvers' method and the opposite Stenvers' method in both the rate of magnification and the clinical evaluation. The increase in lens dose with the opposite Stenvers' method was not significant. We concluded that the opposite Stenvers' method was useful.
AB - In otorthinolaryngology, Stenvers' method is employed in radiography of the pyramid (internal acoustic meatus and semicircular canals). However, in cases of dizziness, where the prone position is difficult to achieve, we occasionally use the opposite Stenvers' method instead of the conventional one. This makes it possible to perform radiography with the patient in the supine position. Compared with the conventional Stenvers' method, the problems of this method were increases not only in the rate of magnification but also in lens dose. In this study, we evaluated these problems by employing computed tomography (CT) and a glass dosimeter with phantom as well as by clinical evaluation. The results showed no statistically significant difference between Stenvers' method and the opposite Stenvers' method in both the rate of magnification and the clinical evaluation. The increase in lens dose with the opposite Stenvers' method was not significant. We concluded that the opposite Stenvers' method was useful.
UR - http://www.scopus.com/inward/record.url?scp=0642308020&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0642308020&partnerID=8YFLogxK
U2 - 10.6009/jjrt.KJ00003174217
DO - 10.6009/jjrt.KJ00003174217
M3 - Article
C2 - 12937409
AN - SCOPUS:0642308020
SN - 0369-4305
VL - 59
SP - 872
EP - 878
JO - Nippon Hoshasen Gijutsu Gakkai zasshi
JF - Nippon Hoshasen Gijutsu Gakkai zasshi
IS - 7
ER -