TY - JOUR
T1 - Time-of-flight information improved the detectability of subcentimeter spheres using a clinical PET/CT scanner
AU - Hashimoto, Naoki
AU - Morita, Keishin
AU - Tsutsui, Yuji
AU - Himuro, Kazuhiko
AU - Baba, Shingo
AU - Sasaki, Masayuki
N1 - Publisher Copyright:
© 2018 by the Society of Nuclear Medicine and Molecular Imaging.
PY - 2018/9/1
Y1 - 2018/9/1
N2 - Recent advancements in clinical PET/CT scanners have improved the detectability of small lesions. However, the ideal reconstruction parameters for detecting small lesions have not yet been sufficiently clarified. The purpose of this study was to investigate the detectability of subcentimeter spheres using a clinical PET/CT scanner. Methods: We used a clinical PET/CT scanner to obtain the data of a National Electrical Manufacturers Association body phantom consisting of 6 small spheres (inner diameters, 4.0, 5.0, 6.2, 7.9, 10, and 37 mm) containing 18F solution. The background activity was 2.65 kBq/mL, and the sphere-to-background ratio was 8. The PET data obtained for 2 and 120 min were reconstructed using ordered-subsets expectation maximization (OSEM), OSEM 1 point-spread function (PSF), and OSEM 1 time-of-flight (TOF) with voxel sizes of 2.04 × 2.04 × 2.00 mm (2-mm voxels) and 4.07 × 4.07 × 3.99 mm (4-mm voxels). A gaussian filter was not used. The image quality was evaluated by visual assessment, as well as by physical assessment of the detectability index and recovery coefficients. Results: According to the visual assessment, the detectability of the spheres improved using TOF and a longer acquisition. Using the OSEM1TOF model, the smallest visually detected spheres were 5 mm in diameter with a 120-min acquisition and 6 mm in diameter with a 2-min acquisition. According to physical assessment, the detectability of spheres 10 mm or smaller using the OSEM1TOF image was superior to that using the OSEM image. In addition, the detectability of each hot sphere and recovery coefficient with 2-mm voxels was superior to that with 4-mm voxels. Although OSEM1PSF images showed less background noise, detectability and the recovery coefficient were not improved for spheres 8 mm or smaller. Conclusion: The TOF model with 2-mm voxels improved the detectability of subcentimeter hot spheres on a clinical PET/CT scanner.
AB - Recent advancements in clinical PET/CT scanners have improved the detectability of small lesions. However, the ideal reconstruction parameters for detecting small lesions have not yet been sufficiently clarified. The purpose of this study was to investigate the detectability of subcentimeter spheres using a clinical PET/CT scanner. Methods: We used a clinical PET/CT scanner to obtain the data of a National Electrical Manufacturers Association body phantom consisting of 6 small spheres (inner diameters, 4.0, 5.0, 6.2, 7.9, 10, and 37 mm) containing 18F solution. The background activity was 2.65 kBq/mL, and the sphere-to-background ratio was 8. The PET data obtained for 2 and 120 min were reconstructed using ordered-subsets expectation maximization (OSEM), OSEM 1 point-spread function (PSF), and OSEM 1 time-of-flight (TOF) with voxel sizes of 2.04 × 2.04 × 2.00 mm (2-mm voxels) and 4.07 × 4.07 × 3.99 mm (4-mm voxels). A gaussian filter was not used. The image quality was evaluated by visual assessment, as well as by physical assessment of the detectability index and recovery coefficients. Results: According to the visual assessment, the detectability of the spheres improved using TOF and a longer acquisition. Using the OSEM1TOF model, the smallest visually detected spheres were 5 mm in diameter with a 120-min acquisition and 6 mm in diameter with a 2-min acquisition. According to physical assessment, the detectability of spheres 10 mm or smaller using the OSEM1TOF image was superior to that using the OSEM image. In addition, the detectability of each hot sphere and recovery coefficient with 2-mm voxels was superior to that with 4-mm voxels. Although OSEM1PSF images showed less background noise, detectability and the recovery coefficient were not improved for spheres 8 mm or smaller. Conclusion: The TOF model with 2-mm voxels improved the detectability of subcentimeter hot spheres on a clinical PET/CT scanner.
UR - http://www.scopus.com/inward/record.url?scp=85053436396&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85053436396&partnerID=8YFLogxK
U2 - 10.2967/jnmt.117.204735
DO - 10.2967/jnmt.117.204735
M3 - Article
C2 - 29599404
AN - SCOPUS:85053436396
SN - 0091-4916
VL - 46
SP - 268
EP - 273
JO - Journal of nuclear medicine technology
JF - Journal of nuclear medicine technology
IS - 3
ER -