Abstract
In conventional ejector refrigeration cycles, the ejector mostly operates at fixed pressure points in the secondary stream and outlet. Studying the sensitivity of the system to the pressure alternation of the mentioned points has not been investigated. To cover this gap, an extra turboexpander, compressor, and gas cooler were introduced to the conventional ejector layout. It was found that pressurizing the secondary entrance of the ejector could be beneficial to COP if it is not warmer than the gas coolers. Also using the expansion process right after the ejector has the potential to increase the efficiency of the system if the discharge pressure of the ejector reaches supercritical or superheat condition.
Original language | English |
---|---|
Pages (from-to) | 204-212 |
Number of pages | 9 |
Journal | Evergreen |
Volume | 8 |
Issue number | 1 |
DOIs | |
Publication status | Published - Mar 2021 |
All Science Journal Classification (ASJC) codes
- Electronic, Optical and Magnetic Materials
- Ceramics and Composites
- Surfaces, Coatings and Films
- Management, Monitoring, Policy and Law