Sulfur species are major impurities in practical hydrocarbon-based-fuels, chemisorption of which on Ni anode catalysts results in possible performance degradation of SOFC systems. In the present study, degradation of SOFC performance caused by sulfur in prereformed CH 4 has been evaluated under various operational conditions such as current density, fuel utilization, pre-reforming ratio, steam-to-carbon ratio, and operational temperature.