Abstract
A 54-year-old man with persistent chest pain was hospitalized for hypertension and DeBakey type IIIb aortic dissection. The false lumen of the dissection was almost completely thrombosed; however, a penetrating atherosclerotic ulcer (PAU) was observed 5 weeks later. At that time, we successfully embolized the PAU with a microcatheter and interlocking detachable coils (IDCs). The patient is well with no episodes of relapse in 20 months of follow-up. This case suggests the utility of the microcatheter and IDC system as an alternative to surgery.
Original language | English |
---|---|
Pages (from-to) | 391-393 |
Number of pages | 3 |
Journal | CardioVascular and Interventional Radiology |
Volume | 23 |
Issue number | 5 |
DOIs | |
Publication status | Published - Jan 1 2000 |
All Science Journal Classification (ASJC) codes
- Radiology Nuclear Medicine and imaging
- Cardiology and Cardiovascular Medicine