TY - JOUR
T1 - Study on the utilization of heat in the mechanically ventilated Trombe wall in a house with a central air conditioning and air circulation system
AU - Ma, Qingsong
AU - Fukuda, Hiroatsu
AU - Lee, Myonghyang
AU - Kobatake, Takumi
AU - Kuma, Yuko
AU - Ozaki, Akihito
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/7/15
Y1 - 2018/7/15
N2 - This paper presents a study on a mechanically ventilated Trombe wall that adds additional windows to the storage wall. The mechanically ventilated Trombe wall is located on the south side of the house with a central air conditioning and air circulation system. To reduce the heating load, during the heating period, the heat from the Trombe wall air channel is sent to the air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Taking a house located in Miyazaki, Japan as an example, we conducted an actual survey to understand the situation of heat utilization of the Trombe wall and used numerical simulations to examine the effective method of heat utilization of the Trombe wall. Results showed that in all-day air conditioning, even when sending the air in the Trombe wall to the air-conditioned room, the temperature of the Trombe wall remained high. The heating load was reduced by sending the air from the Trombe wall to the central air-conditioned room and installing the large heat capacity material on the floor in the Trombe wall.
AB - This paper presents a study on a mechanically ventilated Trombe wall that adds additional windows to the storage wall. The mechanically ventilated Trombe wall is located on the south side of the house with a central air conditioning and air circulation system. To reduce the heating load, during the heating period, the heat from the Trombe wall air channel is sent to the air conditioning room, from where it is then distributed and stored throughout the house by way of air circulation. Taking a house located in Miyazaki, Japan as an example, we conducted an actual survey to understand the situation of heat utilization of the Trombe wall and used numerical simulations to examine the effective method of heat utilization of the Trombe wall. Results showed that in all-day air conditioning, even when sending the air in the Trombe wall to the air-conditioned room, the temperature of the Trombe wall remained high. The heating load was reduced by sending the air from the Trombe wall to the central air-conditioned room and installing the large heat capacity material on the floor in the Trombe wall.
UR - http://www.scopus.com/inward/record.url?scp=85045711329&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85045711329&partnerID=8YFLogxK
U2 - 10.1016/j.apenergy.2018.04.010
DO - 10.1016/j.apenergy.2018.04.010
M3 - Article
AN - SCOPUS:85045711329
SN - 0306-2619
VL - 222
SP - 861
EP - 871
JO - Applied Energy
JF - Applied Energy
ER -