@inproceedings{3310a3d7842a41538a0d8e8b384fa1b5,
title = "Study on response function of organic liquid scintillator for high-energy neutrons",
abstract = "Response functions of liquid organic scintillator for neutrons up to 800 MeV have been measured at the Heavy-Ion Medical Accelerator in Chiba (HIMAC) of National Institute of Radiological Sciences (NIRS). 800-MeV/u Si ions and 400-MeV/u C ions bombarded a thick carbon target to produce neutrons. The kinetic energies of emitted neutrons were determined by the time-of-flight (TOF) method. Light output for neutrons was evaluated by eliminating events due to gamma-rays and charged particles. The measured response functions were compared with calculations using SCINFUL-QMD and CECIL codes. It was found that SCINFUL-QMD reproduced our experimental data adequately.",
author = "Daiki Satoh and Tatsuhiko Sato and Akira Endo and Yasuhiro Yamaguchi and Masashi Takada and Kenji Ishibashi",
year = "2005",
month = may,
day = "24",
doi = "10.1063/1.1945332",
language = "English",
isbn = "073540254X",
series = "AIP Conference Proceedings",
pages = "1680--1683",
booktitle = "International Conference on Nuclear Data for Science and Technology",