Abstract
An experimental investigation is conducted on the tensile cyclic behavior of metal impregnated composites based on a preformed yarn method such as Cu-C/C and Si-C/C together with C/C. Specimens are loaded cyclically in tension and tension. Their S-N curves and the fatigue strength of about 0.8UTS at around N = 104 were obtained. Macroscopic and microscopic characteristics are discussed to yield the cyclic failure mechanism as follows. In a low cycle region, the decrease of shear resistance caused by wear at the fiber/matrix interface increases the probability of fiber break, while after about 104 cycles the smoother interface and longer debonding area suppress the decrease of shear resistance. Thus, the probability of fiber break does not increase.
| Original language | English |
|---|---|
| Pages (from-to) | 3070-3082 |
| Number of pages | 13 |
| Journal | Composites Science and Technology |
| Volume | 66 |
| Issue number | 15 |
| DOIs | |
| Publication status | Published - Dec 1 2006 |
All Science Journal Classification (ASJC) codes
- Ceramics and Composites
- General Engineering
Fingerprint
Dive into the research topics of 'Strength of metal impregnated C/C under tensile cyclic loading'. Together they form a unique fingerprint.Cite this