TY - GEN
T1 - Soft x-ray beam line for industry application in saga
AU - Kamada, M.
AU - Azuma, J.
AU - Takahashi, K.
AU - Kondo, Y.
AU - Miyata, H.
AU - Tsuji, J.
AU - Hashimoto, H.
AU - Yamashige, H.
AU - Kurisaki, S.
AU - Wakita, H.
AU - Furuya, K.
AU - Harata, A.
AU - Tochihara, H.
AU - Matsuo, S.
AU - Watanabe, T.
AU - Inaba, M.
AU - Okajima, T.
AU - Setoyama, H.
AU - Yoshimura, D.
AU - Fujimoto, H.
PY - 2007
Y1 - 2007
N2 - The varied line spacing plane grating monochromator (VLS-PGM) has been constructed for an industry application beamline using soft x-rays from the 1.4 GeV storage ring in Saga, which is the first synchrotron in Kyushu Island. The design aim of the VLS-PGM is to cover the wide-energy range from 40-1,000 eV and also to have medium resolving power, high throughput, better reproducibility and suppression of higher-order light. In order to cover the wide energy range with suppressing higher-order light, a set of three focusing mirrors and one grating is installed. The resolving power expected from the ray-tracing calculation using SHADOW is more than 5,000 with 10 micron slits. The conventional photoelectron spectrometer is installed with an ion gun, a flood gun and a twin-anode x-ray source. The instrument for XAFS measurement is also attached to the main chamber.
AB - The varied line spacing plane grating monochromator (VLS-PGM) has been constructed for an industry application beamline using soft x-rays from the 1.4 GeV storage ring in Saga, which is the first synchrotron in Kyushu Island. The design aim of the VLS-PGM is to cover the wide-energy range from 40-1,000 eV and also to have medium resolving power, high throughput, better reproducibility and suppression of higher-order light. In order to cover the wide energy range with suppressing higher-order light, a set of three focusing mirrors and one grating is installed. The resolving power expected from the ray-tracing calculation using SHADOW is more than 5,000 with 10 micron slits. The conventional photoelectron spectrometer is installed with an ion gun, a flood gun and a twin-anode x-ray source. The instrument for XAFS measurement is also attached to the main chamber.
UR - http://www.scopus.com/inward/record.url?scp=33947391615&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33947391615&partnerID=8YFLogxK
U2 - 10.1063/1.2436138
DO - 10.1063/1.2436138
M3 - Conference contribution
AN - SCOPUS:33947391615
SN - 0735403732
SN - 9780735403734
T3 - AIP Conference Proceedings
SP - 623
EP - 626
BT - SYNCHROTRON RADIATION INSTRUMENTATION
T2 - SYNCHROTRON RADIATION INSTRUMENTATION: 9th International Conference on Synchrotron Radiation Instrumentation
Y2 - 28 May 2006 through 28 June 2006
ER -