Abstract
Fracture and small crack behavior in the very high cycle domain of 10 9 cycles were investigated with a nickel-based superalloy under ultrasonic fatigue in ambient air at room temperature. The influence of ultrasonic frequency is examined by comparing the results with those in conventional low frequency fatigue. It is found that fatigue strength increases as frequency is raised up to 19.5 kHz and the most of fatigue life is consumed in nucleating and propagating small cracks up to 100 μm. Transition of fracture mode from transgranular ductile fracture to cleavage-dominated fracture occurs beyond a critical stress intensity factor range of approximately 21MPam, leading to the catastrophic failure under ultrasonic fatigue.
| Original language | English |
|---|---|
| Pages (from-to) | 1227-1232 |
| Number of pages | 6 |
| Journal | International Journal of Fatigue |
| Volume | 27 |
| Issue number | 10-12 |
| DOIs | |
| Publication status | Published - Oct 2005 |
| Externally published | Yes |
| Event | Fatigue Damage of Structural Materials V - Duration: Sept 19 2004 → Sept 24 2004 |
All Science Journal Classification (ASJC) codes
- Modelling and Simulation
- General Materials Science
- Mechanics of Materials
- Mechanical Engineering
- Industrial and Manufacturing Engineering
Fingerprint
Dive into the research topics of 'Small crack behavior and fracture of nickel-based superalloy under ultrasonic fatigue'. Together they form a unique fingerprint.Cite this