T1 - Simultaneous potentiometric determination of ClO3/--ClO2/- and ClO3/--HClO by flow injection analysis using Fe(III)-Fe(II) potential buffer
AU - Ohura, Hiroki
AU - Imato, Toshihiko
AU - Yamasaki, Sumio
PY - 1999/8
Y1 - 1999/8
N2 - A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3/--ClO2/- and ClO3/- HClO has been developed, using both a redox electrode detector and a Fe(III)- Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2/- obtained by the transient potential change were enhanced 700-800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2/- is as low as 5 x 10-8 M with use of a 5 x 10-4 M Fe(III)-1 x 10-3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3/- was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3/- was 2 x 10-6 M with the use of a 5 x 10-4 M Fe(III)-1 x 10-3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3 --ClO2/- or ClO3/--HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2 x 10-5-2 x 10-4 M for ClO3/-, and 1 x 10-6-1 x 10-5 M for HClO and ClO2/-. The reproducibility of the present method was in the range 1.5-2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3/- added to the sample.
AB - A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3/--ClO2/- and ClO3/- HClO has been developed, using both a redox electrode detector and a Fe(III)- Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2/- obtained by the transient potential change were enhanced 700-800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2/- is as low as 5 x 10-8 M with use of a 5 x 10-4 M Fe(III)-1 x 10-3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3/- was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3/- was 2 x 10-6 M with the use of a 5 x 10-4 M Fe(III)-1 x 10-3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3 --ClO2/- or ClO3/--HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2 x 10-5-2 x 10-4 M for ClO3/-, and 1 x 10-6-1 x 10-5 M for HClO and ClO2/-. The reproducibility of the present method was in the range 1.5-2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3/- added to the sample.
UR - http://www.scopus.com/inward/record.url?scp=0033538882&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033538882&partnerID=8YFLogxK
U2 - 10.1016/S0039-9140(99)00018-1
DO - 10.1016/S0039-9140(99)00018-1
M3 - Article
C2 - 18967677
AN - SCOPUS:0033538882
SN - 0039-9140
VL - 49
SP - 1003
EP - 1015
JO - Talanta
JF - Talanta
IS - 5
ER -