TY - JOUR
T1 - Selective determination of sultopride in human plasma using high-performance liquid chromatography with ultraviolet detection and particle beam mass spectrometry
AU - Jitsufuchi, Narumi
AU - Kudo, Keiko
AU - Tokunaga, Hironori
AU - Imamura, Tohru
PY - 1997/3/7
Y1 - 1997/3/7
N2 - We developed a sensitive and selective method for determining levels of sultopride, a neuroleptic drug of the substituted benzamide, in human plasma using high-performance liquid chromatography (HPLC) combined with UV detection and particle beam mass spectrometry (PBMS). Sultopride was extracted with tert.-butylmethyl ether using a salting-out technique. Tiapride served as an internal standard (I.S.). Sultopride and I.S. were separated by HPLC on a silica column with a mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear over the concentration range from 5 to 1000 ng/ml by HPLC with UV detection and from 10 to 1000 ng/ml with PBMS detection. The limit of quantitation was 5 ng/ml with UV detection and 10 ng/ml with PBMS detection. The absolute recovery was 92% and the within-day coefficients of variation were 2.9-7.1% at plasma concentrations from 50 to 500 ng/ml, determined by HPLC with UV detection. Using this method, we measured the plasma concentrations of sultopride with replicate analyses in four hospitalized patients and steady-state plasma levels were determined to be 161.6 ± 30.8, 321.1 ± 93.7, 726.5 ± 143.1 and 1273.6 ± 211.2 ng/ml, respectively.
AB - We developed a sensitive and selective method for determining levels of sultopride, a neuroleptic drug of the substituted benzamide, in human plasma using high-performance liquid chromatography (HPLC) combined with UV detection and particle beam mass spectrometry (PBMS). Sultopride was extracted with tert.-butylmethyl ether using a salting-out technique. Tiapride served as an internal standard (I.S.). Sultopride and I.S. were separated by HPLC on a silica column with a mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear over the concentration range from 5 to 1000 ng/ml by HPLC with UV detection and from 10 to 1000 ng/ml with PBMS detection. The limit of quantitation was 5 ng/ml with UV detection and 10 ng/ml with PBMS detection. The absolute recovery was 92% and the within-day coefficients of variation were 2.9-7.1% at plasma concentrations from 50 to 500 ng/ml, determined by HPLC with UV detection. Using this method, we measured the plasma concentrations of sultopride with replicate analyses in four hospitalized patients and steady-state plasma levels were determined to be 161.6 ± 30.8, 321.1 ± 93.7, 726.5 ± 143.1 and 1273.6 ± 211.2 ng/ml, respectively.
UR - http://www.scopus.com/inward/record.url?scp=0030959449&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030959449&partnerID=8YFLogxK
U2 - 10.1016/S0378-4347(96)00423-9
DO - 10.1016/S0378-4347(96)00423-9
M3 - Article
C2 - 9106039
AN - SCOPUS:0030959449
SN - 1572-6495
VL - 690
SP - 153
EP - 159
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 1-2
ER -