TY - JOUR
T1 - Regional Differences in Tear Film Stability and Meibomian Glands in Patients with Aqueous-Deficient Dry Eye
AU - Koh, Shizuka
AU - Ikeda, Chikako
AU - Fujimoto, Hisataka
AU - Oie, Yoshinori
AU - Soma, Takeshi
AU - Maeda, Naoyuki
AU - Nishida, Kohji
N1 - Publisher Copyright:
© 2015 Contact Lens Association of Ophthalmologists.
PY - 2016/7/1
Y1 - 2016/7/1
N2 - Objectives: To noninvasively investigate regional differences in tear film stability and meibomian glands in patients with aqueous-deficient dry eye. Methods: Forty-nine dry eyes and 31 normal eyes were analyzed. A corneal topographer with a tear film scanning function was used for noninvasive tear film break-up time (NI-TFBUT) measurements and meibomian gland observations. The NI-TFBUT values and location of the first tear film break-up point were recorded in four quadrants. Meibomian gland loss was graded for each eyelid using meiboscores. Lid margin abnormality was scored from zero to four according to the number of existing abnormalities. The NI-TFBUT values and meiboscores were compared between two groups, and regional differences in NI-TFBUT values and meiboscores were analyzed. Also, the correlation between the NI-TFBUT and ocular surface examination results were investigated. Results: The NI-TFBUT values and meiboscores were significantly lower and higher, respectively, for the dry eye group than for the normal group. In the dry eye group, the occurrence rate for first tear film break-up was the highest in the inferior nasal quadrant, and the mean meiboscore was significantly higher for the upper eyelids than for the lower eyelids. The NI-TFBUT and lid margin abnormality scores showed a weak negative correlation, and the NI-TFBUT values and meiboscores showed no correlation. Conclusions: Compared to normal eyes, aqueous-deficient dry eyes show significant regional differences in tear film stability and meibomian glands. Considering these regional differences, the overall observation of the ocular surface, including both upper and lower eyelids, will aid clinicians in understanding this condition better.
AB - Objectives: To noninvasively investigate regional differences in tear film stability and meibomian glands in patients with aqueous-deficient dry eye. Methods: Forty-nine dry eyes and 31 normal eyes were analyzed. A corneal topographer with a tear film scanning function was used for noninvasive tear film break-up time (NI-TFBUT) measurements and meibomian gland observations. The NI-TFBUT values and location of the first tear film break-up point were recorded in four quadrants. Meibomian gland loss was graded for each eyelid using meiboscores. Lid margin abnormality was scored from zero to four according to the number of existing abnormalities. The NI-TFBUT values and meiboscores were compared between two groups, and regional differences in NI-TFBUT values and meiboscores were analyzed. Also, the correlation between the NI-TFBUT and ocular surface examination results were investigated. Results: The NI-TFBUT values and meiboscores were significantly lower and higher, respectively, for the dry eye group than for the normal group. In the dry eye group, the occurrence rate for first tear film break-up was the highest in the inferior nasal quadrant, and the mean meiboscore was significantly higher for the upper eyelids than for the lower eyelids. The NI-TFBUT and lid margin abnormality scores showed a weak negative correlation, and the NI-TFBUT values and meiboscores showed no correlation. Conclusions: Compared to normal eyes, aqueous-deficient dry eyes show significant regional differences in tear film stability and meibomian glands. Considering these regional differences, the overall observation of the ocular surface, including both upper and lower eyelids, will aid clinicians in understanding this condition better.
UR - http://www.scopus.com/inward/record.url?scp=84944345570&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84944345570&partnerID=8YFLogxK
U2 - 10.1097/ICL.0000000000000191
DO - 10.1097/ICL.0000000000000191
M3 - Article
AN - SCOPUS:84944345570
SN - 1542-2321
VL - 42
SP - 250
EP - 255
JO - Eye and Contact Lens
JF - Eye and Contact Lens
IS - 4
ER -