Real-time ureteral identification with novel, versatile, and inexpensive catheter

Yuki Ushimaru, Atsushi Ohigawa, Kotaro Yamashita, Takuro Saito, Koji Tanaka, Tomoki Makino, Tsuyoshi Takahashi, Yukinori Kurokawa, Makoto Yamasaki, Masaki Mori, Yuichiro Doki, Kiyokazu Nakajima

Research output: Contribution to journalArticlepeer-review

5 Citations (Scopus)

Abstract

Background: Although ureteral catheters and ureteral fluorescence methods have been investigated to avoid ureteral injury, they have not been standardized for procedural complexity and safety to the living body. A near-infrared (NIR) fluorescence ureteral catheter made of fluorescent resin was jointly developed for non-invasive detection of ureters. The aims of this study were to (1) evaluate its bench-top performance and (2) assert its safety and potential usefulness in a series of animal models. Methods: [Bench-top study]: Confirmed stimulation of NIR fluorescence catheter by NIR light was investigated with the use of a laparoscopic fluorescence imaging system. Additionally, the influence of imaging distance and shielding objects, such as 1.5-mm sliced pig loin with multiple sheets, was also evaluated. [Performance study]: The safety and potential usefulness of fluorescence catheter was evaluated in five pigs. Non-fluorescence and fluorescence ureteral catheters were alternatively placed in the animals’ left and right ureters. The ImageJ software was used in all experiments to quantify fluorescence signal and the signal-to-background ratio. Results: [Bench-top study]: The fluorescence ureteral catheter was successfully identified at all distances. Its fluorescence decreased in inverse proportion to distance and to the intervening shield thickness (p < 0.01). When shields were present, catheter position could not be recognized with non-fluorescence catheters, but with fluorescence catheters they could be recognized. [Performance study]: Fluorescence catheter’s ability to fluoresce at all distances was confirmed (p < 0.01). No individual differences (p = 0.21) or left/right ureter differences (p = 0.79) were observed. The fluorescence of the fluorescence catheter decreased in inverse proportion to distance (p < 0.01). Conclusions: The new fluorescence ureter catheter investigated shows promising performance in providing ureteral identification with high specificity during laparoscopic surgery.

Original languageEnglish
Pages (from-to)3669-3678
Number of pages10
JournalSurgical endoscopy
Volume34
Issue number8
DOIs
Publication statusPublished - Aug 1 2020

All Science Journal Classification (ASJC) codes

  • Surgery

Fingerprint

Dive into the research topics of 'Real-time ureteral identification with novel, versatile, and inexpensive catheter'. Together they form a unique fingerprint.

Cite this