N2 - Radiofrequency (RF) ablation is increasingly being used to treat liver cancer because it is minimally invasive. However, it is difficult for operators to control the size of the coagulation zones precisely, because no method has been established to form an adequate and suitable ablation area. To overcome this limitation, we propose a new system that can control the coagulation zone size. The system operates as follows: 1) the liver temperature is estimated using a temperature-distribution simulator to reduce invasiveness; 2) the output power of the RF generator is controlled automatically according to the liver temperature. To use this system in real time, both the time taken to calculate the temperature in the simulation and the control accuracy are important. We therefore investigated the relationship between the time interval required to change the output voltage and temperature control stability in RF ablation. The results revealed that the proposed method can control the temperature at a point away from the electrode needle to obtain the desired ablation size. It was also shown to be necessary to reduce the time interval when small tumors are cauterized to avoid excessive treatment. In contrast, such high frequency feedback control is not required when large tumors are cauterized.
AB - Radiofrequency (RF) ablation is increasingly being used to treat liver cancer because it is minimally invasive. However, it is difficult for operators to control the size of the coagulation zones precisely, because no method has been established to form an adequate and suitable ablation area. To overcome this limitation, we propose a new system that can control the coagulation zone size. The system operates as follows: 1) the liver temperature is estimated using a temperature-distribution simulator to reduce invasiveness; 2) the output power of the RF generator is controlled automatically according to the liver temperature. To use this system in real time, both the time taken to calculate the temperature in the simulation and the control accuracy are important. We therefore investigated the relationship between the time interval required to change the output voltage and temperature control stability in RF ablation. The results revealed that the proposed method can control the temperature at a point away from the electrode needle to obtain the desired ablation size. It was also shown to be necessary to reduce the time interval when small tumors are cauterized to avoid excessive treatment. In contrast, such high frequency feedback control is not required when large tumors are cauterized.
UR - http://www.scopus.com/inward/record.url?scp=84938097083&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84938097083&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2013.6609519
DO - 10.1109/EMBC.2013.6609519
M3 - Article
C2 - 24109706
SN - 1557-170X
VL - 2013
SP - 392
EP - 396
JO - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
JF - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference
ER -