Real-time monitoring of dynamic stress concentration by mechanoluminescent sensing film

C. Li, C. Xu, Y. Imai, Wenxue Wang, L. Zhang, H. Yamada

Research output: Contribution to journalConference articlepeer-review

21 Citations (Scopus)

Abstract

In this paper, we demonstrate that a dynamic stress concentration around Lüders band can be directly displayed using mechanoluminescence (ML) sensing film of SrAl2O4:Eu (SAO) coated on the surface of metal. Uniaxial tensile test of an aluminum alloy (2.5% Mg) plate coated with the SAO sensing film was performed and the ML images were recorded using a high-speed camera. Captured ML images confirmed the formation and propagation of Lüders band clearly in real time.

Original languageEnglish
Pages (from-to)247-250
Number of pages4
JournalApplied Mechanics and Materials
Volume13-14
DOIs
Publication statusPublished - 2008
Event6th International Conference on Advances in Experimental Mechanics - London, United Kingdom
Duration: Sept 9 2008Sept 11 2008

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Fingerprint

Dive into the research topics of 'Real-time monitoring of dynamic stress concentration by mechanoluminescent sensing film'. Together they form a unique fingerprint.

Cite this