TY - JOUR
T1 - Quantitative estimation of biological cell concentration suspended in aqueous medium by using dielectrophoretic impedance measurement method
AU - Suehiro, Junya
AU - Yatsunami, Ryuichi
AU - Hamada, Ryo
AU - Hara, Masanori
N1 - Copyright:
Copyright 2004 Elsevier Science B.V., Amsterdam. All rights reserved.
PY - 1999/11/7
Y1 - 1999/11/7
N2 - We describe a new technique that realizes the quantitative estimation of the biological cell concentration in an aqueous medium. The proposed dielectrophoretic impedance measurement method utilizes the positive dielectrophoretic force to capture suspended biological particles onto an interdigitated micro-electrode array in pearl-chain formation. Higher cell concentration results in faster development of the pearl chains, which are electrically connected in parallel within the electrode gap to increase the conductance and capacitance between the electrodes. By monitoring temporal variation of the electrical impedance, it is possible to quantitatively evaluate the cell population according to a theoretical model of the cell collection process. It has been demonstrated that a suspension liquid of Escherichia coli could be accurately assayed in about 10 min at 105 cm-3 concentration.
AB - We describe a new technique that realizes the quantitative estimation of the biological cell concentration in an aqueous medium. The proposed dielectrophoretic impedance measurement method utilizes the positive dielectrophoretic force to capture suspended biological particles onto an interdigitated micro-electrode array in pearl-chain formation. Higher cell concentration results in faster development of the pearl chains, which are electrically connected in parallel within the electrode gap to increase the conductance and capacitance between the electrodes. By monitoring temporal variation of the electrical impedance, it is possible to quantitatively evaluate the cell population according to a theoretical model of the cell collection process. It has been demonstrated that a suspension liquid of Escherichia coli could be accurately assayed in about 10 min at 105 cm-3 concentration.
UR - http://www.scopus.com/inward/record.url?scp=0033345559&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033345559&partnerID=8YFLogxK
U2 - 10.1088/0022-3727/32/21/316
DO - 10.1088/0022-3727/32/21/316
M3 - Article
AN - SCOPUS:0033345559
SN - 0022-3727
VL - 32
SP - 2814
EP - 2820
JO - Journal of Physics D: Applied Physics
JF - Journal of Physics D: Applied Physics
IS - 21
ER -