TY - JOUR
T1 - Probing the inner structure of blast furnace by cosmic-ray muon radiography
AU - Shinotake, Akihiko
AU - Matsuzaki, Shinroku
AU - Kunitomo, Kazuya
AU - Naito, Masaaki
AU - Hashimoto, Misao
AU - Hatanaka, Asao
AU - Nagane, Toshihiro
AU - Nagamine, Kanetada
AU - Tanaka, Hiroyuki
N1 - Copyright:
Copyright 2012 Elsevier B.V., All rights reserved.
PY - 2009
Y1 - 2009
N2 - The visualization of the inner state of a blast furnace was investigated by exploiting the feature of cosmic-ray muon that attenuates according to the density and the thickness of the object through which it penetrates. The distribution of the cosmic-ray muon accumulated in an object in a blast furnace during a certain period has been determined by a probing system provided with two sets of a pair of panels with plastic scintillation counters segmented in parallel along each direction of both sides. First, measurement was performed in the furnace hearth structure that had been taken out after the shutdown of Oita No. 2 Blast Furnace repaired in 2004. Next, another measurement was performed in the same manner in the renewed furnace hearth of Oita No. 2 Blast Furnace which had just started working after its repairs. The density of the material at the iron-rich portion inside the hearth was estimated from the accumulation ratio obtained from the relation between the intensity of the muon channel passing through the iron-rich part in the hearth and that passing through its opposite channel symmetric to the coordinate origin. Then, the level of the furnace bottom brick, meaning its eroded thickness, was estimated from those accumulation ratios in relation to each channel crossing both the iron-rich part and the furnace bottom brick. The possibility of the density distribution of the material inside a blast furnace and the remaining thickness of bricks being estimated by this measurement method was identified.
AB - The visualization of the inner state of a blast furnace was investigated by exploiting the feature of cosmic-ray muon that attenuates according to the density and the thickness of the object through which it penetrates. The distribution of the cosmic-ray muon accumulated in an object in a blast furnace during a certain period has been determined by a probing system provided with two sets of a pair of panels with plastic scintillation counters segmented in parallel along each direction of both sides. First, measurement was performed in the furnace hearth structure that had been taken out after the shutdown of Oita No. 2 Blast Furnace repaired in 2004. Next, another measurement was performed in the same manner in the renewed furnace hearth of Oita No. 2 Blast Furnace which had just started working after its repairs. The density of the material at the iron-rich portion inside the hearth was estimated from the accumulation ratio obtained from the relation between the intensity of the muon channel passing through the iron-rich part in the hearth and that passing through its opposite channel symmetric to the coordinate origin. Then, the level of the furnace bottom brick, meaning its eroded thickness, was estimated from those accumulation ratios in relation to each channel crossing both the iron-rich part and the furnace bottom brick. The possibility of the density distribution of the material inside a blast furnace and the remaining thickness of bricks being estimated by this measurement method was identified.
UR - http://www.scopus.com/inward/record.url?scp=72749090882&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=72749090882&partnerID=8YFLogxK
U2 - 10.2355/tetsutohagane.95.665
DO - 10.2355/tetsutohagane.95.665
M3 - Article
AN - SCOPUS:72749090882
SN - 0021-1575
VL - 95
SP - 665
EP - 671
JO - Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan
JF - Tetsu-To-Hagane/Journal of the Iron and Steel Institute of Japan
IS - 10
ER -