TY - JOUR
T1 - Predictors and proarrhythmic consequences of inappropriate implantable cardioverter-defibrillator therapy
AU - Tenma, Taro
AU - Yokoshiki, Hisashi
AU - Mizukami, Kazuya
AU - Mitsuyama, Hirofumi
AU - Watanabe, Masaya
AU - Sasaki, Ryo
AU - Maeno, Motoki
AU - Matsui, Yoshiro
AU - Tsutsui, Hiroyuki
N1 - Publisher Copyright:
© 2015, Japanese Circulation Society. All rights reserved.
Copyright:
Copyright 2015 Elsevier B.V., All rights reserved.
PY - 2015/8/25
Y1 - 2015/8/25
N2 - Background: Despite the benefits of implantable cardioverter-defibrillator (ICD) therapy, inappropriate shocks can lead to multiple adverse effects. The aim of this study was to clarify the predictors of inappropriate ICD shocks and their proarrhythmic consequences. Methods and Results: We retrospectively studied 316 consecutive patients who underwent ICD implantation from December 2000 to December 2011. Of them, 70 (22%) experienced inappropriate ICD shocks without proarrhythmia requiring some intervention; 2 patients (0.6%) had proarrhythmic inappropriate ICD therapy by antitachycardia pacing (ATP), thereby calculated to be 0.18% of patients per year. However, they did not have syncope from this inappropriate ATP. Multivariate analysis identified younger age (≤56 years: hazard ratio [HR] 1.68, 95% confidence interval [CI] 1.02-2.77, P=0.043), paroxysmal atrial fibrillation (HR 3.00, 95% CI 1.64-5.31, P=0.0002), stroke (HR 2.23, 95% CI 1.11-4.47, P=0.024), and no diuretic use (HR 1.72, 95% CI 1.03-2.93, P=0.039) as independent predictors of the occurrence of inappropriate ICD shocks. Conclusions: Young age, paroxysmal atrial fibrillation, stroke, and no use of diuretics were independently associated with inappropriate ICD shocks. Proarrhythmic inappropriate ICD therapy was observed with an annual incidence of 0.18% by ATP.
AB - Background: Despite the benefits of implantable cardioverter-defibrillator (ICD) therapy, inappropriate shocks can lead to multiple adverse effects. The aim of this study was to clarify the predictors of inappropriate ICD shocks and their proarrhythmic consequences. Methods and Results: We retrospectively studied 316 consecutive patients who underwent ICD implantation from December 2000 to December 2011. Of them, 70 (22%) experienced inappropriate ICD shocks without proarrhythmia requiring some intervention; 2 patients (0.6%) had proarrhythmic inappropriate ICD therapy by antitachycardia pacing (ATP), thereby calculated to be 0.18% of patients per year. However, they did not have syncope from this inappropriate ATP. Multivariate analysis identified younger age (≤56 years: hazard ratio [HR] 1.68, 95% confidence interval [CI] 1.02-2.77, P=0.043), paroxysmal atrial fibrillation (HR 3.00, 95% CI 1.64-5.31, P=0.0002), stroke (HR 2.23, 95% CI 1.11-4.47, P=0.024), and no diuretic use (HR 1.72, 95% CI 1.03-2.93, P=0.039) as independent predictors of the occurrence of inappropriate ICD shocks. Conclusions: Young age, paroxysmal atrial fibrillation, stroke, and no use of diuretics were independently associated with inappropriate ICD shocks. Proarrhythmic inappropriate ICD therapy was observed with an annual incidence of 0.18% by ATP.
UR - http://www.scopus.com/inward/record.url?scp=84940093868&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84940093868&partnerID=8YFLogxK
U2 - 10.1253/circj.CJ-15-0306
DO - 10.1253/circj.CJ-15-0306
M3 - Article
C2 - 26104029
AN - SCOPUS:84940093868
SN - 1346-9843
VL - 79
SP - 1920
EP - 1927
JO - Circulation Journal
JF - Circulation Journal
IS - 9
ER -