TY - JOUR
T1 - Practical non-targeted gas chromatography/mass spectrometry-based metabolomics platform for metabolic phenotype analysis
AU - Tsugawa, Hiroshi
AU - Bamba, Takeshi
AU - Shinohara, Masakazu
AU - Nishiumi, Shin
AU - Yoshida, Masaru
AU - Fukusaki, Eiichiro
N1 - Funding Information:
This study was partly supported by grants from the Global COE Program "Global Center of Excellence for Education and Research in Integrative Membrane Biology" [M.S.] and "Global Center of Excellence for Education and Research on Signal Transduction Medicine in the Coming Generation" [M.Y.] from the Ministry of Education, Culture, Sports, Science, and Technology of Japan . This study was also partly supported by a grant from the program ‘Young researchers training program for promoting innovation’ of Special Coordination Fund for Promoting Science and Technology from the Ministry of Education, Culture, Sports, Science, and Technology of Japan [S.N., M.Y.].
PY - 2011/9
Y1 - 2011/9
N2 - Gas chromatography coupled to mass spectrometry (GC/MS) is a core analytical method for metabolomics and has been used as a platform in non-targeted analysis, especially for hydrophilic metabolites. Non-targeted GC/MS-based metabolomics generally requires a high-throughput technology to handle a large volume of samples and an accumulated database (reference library) of the retention times and mass spectra of standard compounds for accurate peak identification. In this study, we provide a practical GC/MS platform and an auto peak identification technique that is not restricted to certain types of mass spectrometers. The platform utilizes a quadrupole mass spectrometer capable of high-speed scanning, resulting in greater output compared with Pegasus GC-time of flight (TOF)/MS, which has been an essential instrument for high-throughput experiments. Moreover, we show that our reference library is broadly applicable to other instruments; peak identification can be readily performed using the library without constructing a reference resource. The usefulness and versatility of our system are demonstrated by the analyses of three experimental metabolomics data sets, including standard mixtures and real biological samples.
AB - Gas chromatography coupled to mass spectrometry (GC/MS) is a core analytical method for metabolomics and has been used as a platform in non-targeted analysis, especially for hydrophilic metabolites. Non-targeted GC/MS-based metabolomics generally requires a high-throughput technology to handle a large volume of samples and an accumulated database (reference library) of the retention times and mass spectra of standard compounds for accurate peak identification. In this study, we provide a practical GC/MS platform and an auto peak identification technique that is not restricted to certain types of mass spectrometers. The platform utilizes a quadrupole mass spectrometer capable of high-speed scanning, resulting in greater output compared with Pegasus GC-time of flight (TOF)/MS, which has been an essential instrument for high-throughput experiments. Moreover, we show that our reference library is broadly applicable to other instruments; peak identification can be readily performed using the library without constructing a reference resource. The usefulness and versatility of our system are demonstrated by the analyses of three experimental metabolomics data sets, including standard mixtures and real biological samples.
UR - http://www.scopus.com/inward/record.url?scp=80052263466&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80052263466&partnerID=8YFLogxK
U2 - 10.1016/j.jbiosc.2011.05.001
DO - 10.1016/j.jbiosc.2011.05.001
M3 - Article
C2 - 21641865
AN - SCOPUS:80052263466
SN - 1389-1723
VL - 112
SP - 292
EP - 298
JO - Journal of Bioscience and Bioengineering
JF - Journal of Bioscience and Bioengineering
IS - 3
ER -