TY - JOUR
T1 - Performance investigation of advanced adsorption desalination cycle with condenser-evaporator heat recovery scheme
AU - Thu, Kyaw
AU - Kim, Young Deuk
AU - Myat, Aung
AU - Chakraborty, Anutosh
AU - Ng, Kim Choon
N1 - Copyright:
Copyright 2014 Elsevier B.V., All rights reserved.
PY - 2013
Y1 - 2013
N2 - Energy or heat recovery schemes are keys for the performance improvement of any heat-activated cycles such as the absorption and adsorption cycles. We present two innovative heat recovery schemes between the condensing and evaporating units of an adsorption desalination (AD) cycle. By recovering the latent heat of condenser and dumping it into the evaporative process of the evaporator, it elevates the evaporating temperature and hence the adsorption pressure seen by the adsorbent. From isotherms, this has an effect of increasing the vapour uptake. In the proposed configurations, one approach is simply to have a run-about water circuit between the condenser and the evaporator and a pump is used to achieve the water circulation. This run-around circuit is a practical method for retrofitting purposes. The second method is targeted towards a new AD cycle where an encapsulated condenser-evaporator unit is employed. The heat transfer between the condensing and evaporative vapour is almost immediate and the processes occur in a fully integrated vessel, thereby minimizing the heat transfer resistances of heat exchangers.
AB - Energy or heat recovery schemes are keys for the performance improvement of any heat-activated cycles such as the absorption and adsorption cycles. We present two innovative heat recovery schemes between the condensing and evaporating units of an adsorption desalination (AD) cycle. By recovering the latent heat of condenser and dumping it into the evaporative process of the evaporator, it elevates the evaporating temperature and hence the adsorption pressure seen by the adsorbent. From isotherms, this has an effect of increasing the vapour uptake. In the proposed configurations, one approach is simply to have a run-about water circuit between the condenser and the evaporator and a pump is used to achieve the water circulation. This run-around circuit is a practical method for retrofitting purposes. The second method is targeted towards a new AD cycle where an encapsulated condenser-evaporator unit is employed. The heat transfer between the condensing and evaporative vapour is almost immediate and the processes occur in a fully integrated vessel, thereby minimizing the heat transfer resistances of heat exchangers.
UR - http://www.scopus.com/inward/record.url?scp=84875802627&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84875802627&partnerID=8YFLogxK
U2 - 10.1080/19443994.2012.693659
DO - 10.1080/19443994.2012.693659
M3 - Article
AN - SCOPUS:84875802627
SN - 1944-3994
VL - 51
SP - 150
EP - 163
JO - Desalination and Water Treatment
JF - Desalination and Water Treatment
IS - 1-3
ER -