TY - JOUR
T1 - Optimal Frequency of Low-Frequency Eddy-Current Testing for Detecting Defects on the Backside of Thick Steel Plates
AU - Yoshimura, Wataru
AU - Sasayama, Teruyoshi
AU - Enpuku, Keiji
N1 - Funding Information:
ACKNOWLEDGMENT This work was supported by “the Council for Science, Technology and Innovation, Cross-Ministerial Strategic Innovation Promotion Program, Infrastructure Maintenance, Renovation, and Management through JST.”
Publisher Copyright:
© 1965-2012 IEEE.
PY - 2019/7
Y1 - 2019/7
N2 - Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.
AB - Defect detection on the backside of thick steel plates is essential for the safety maintenance of most infrastructures in which they are used. Eddy-current testing (ECT) is a promising method to detect the defects in a steel plate, and inspections at low frequencies are necessary to suppress the skin effect. However, if the frequency is reduced further, the signal from the detection coil also becomes smaller. Therefore, we assessed the optimal frequency for the detection of slit defects on the backside of a 10 mm thick steel plate based on experiments and electromagnetic simulations using the finite-element method. The results suggest that the optimal frequency to detect the defects is approximately 8-10 Hz when the height of the slit exceeds 6 mm. Similarly, in the simulation, the signal was maximized when the frequency was 8-10 Hz, which validates the experimental results. Furthermore, we propose a method to emphasize the deeper defects using multi-frequency data as a fundamental study. The results show that the backside defects are depicted more clearly.
UR - http://www.scopus.com/inward/record.url?scp=85067806730&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85067806730&partnerID=8YFLogxK
U2 - 10.1109/TMAG.2019.2896590
DO - 10.1109/TMAG.2019.2896590
M3 - Article
AN - SCOPUS:85067806730
SN - 0018-9464
VL - 55
JO - IEEE Transactions on Magnetics
JF - IEEE Transactions on Magnetics
IS - 7
M1 - 8645817
ER -