TY - JOUR
T1 - Multiphoton versus confocal high resolution z-sectioning of enhanced green fluorescent microtubules
T2 - Increased multiphoton photobleaching within the focal plane can be compensated using a Pockels cell and dual widefield detectors
AU - Drummond, D. R.
AU - Carter, N.
AU - Cross, R. A.
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2002
Y1 - 2002
N2 - Multiphoton excitation was originally projected to improve live cell fluorescence imaging by minimizing photobleaching effects outside the focal plane, yet reports suggest that photobleaching within the focal plane is actually worse than with one photon excitation. We confirm that when imaging enhanced green fluorescent protein, photobleaching is indeed more acute within the multiphoton excitation volume, so that whilst fluorescence increases as predicted with the square of the excitation power, photobleaching rates increase with a higher order relationship. Crucially however, multiphoton excitation also affords unique opportunities for substantial improvements to fluorescence detection. By using a Pockels cell to minimize exposure of the specimen together with multiple nondescanned detectors we show quantitatively that for any particular bleach rate multiphoton excitation produces significantly more signal than one photon excitation confocal microscopy in high resolution Z-axis sectioning of thin samples. Both modifications are readily implemented on a commercial multiphoton microscope system.
AB - Multiphoton excitation was originally projected to improve live cell fluorescence imaging by minimizing photobleaching effects outside the focal plane, yet reports suggest that photobleaching within the focal plane is actually worse than with one photon excitation. We confirm that when imaging enhanced green fluorescent protein, photobleaching is indeed more acute within the multiphoton excitation volume, so that whilst fluorescence increases as predicted with the square of the excitation power, photobleaching rates increase with a higher order relationship. Crucially however, multiphoton excitation also affords unique opportunities for substantial improvements to fluorescence detection. By using a Pockels cell to minimize exposure of the specimen together with multiple nondescanned detectors we show quantitatively that for any particular bleach rate multiphoton excitation produces significantly more signal than one photon excitation confocal microscopy in high resolution Z-axis sectioning of thin samples. Both modifications are readily implemented on a commercial multiphoton microscope system.
UR - http://www.scopus.com/inward/record.url?scp=0036092056&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036092056&partnerID=8YFLogxK
U2 - 10.1046/j.1365-2818.2002.01024.x
DO - 10.1046/j.1365-2818.2002.01024.x
M3 - Article
C2 - 12000556
AN - SCOPUS:0036092056
SN - 0022-2720
VL - 206
SP - 161
EP - 169
JO - Journal of Microscopy
JF - Journal of Microscopy
IS - 2
ER -